Installing The 9C306 System Monitor - Cabletron Systems 9C106 Setup And Installation Manual

Smartswitch 9000-6 slot chassis
Table of Contents

Advertisement

Installing the 9C306 System Monitor

The 9C306 System Monitor is installed in the slot marked SM on the right front
side of the SmartSwitch 9000-6 Slot chassis, as shown in Figure 2-3.
Install a System Monitor by following the steps below:
The ESD (Electrostatic Discharge) wrist strap should be attached before handling
the System Monitor Module or SmartSwitch 9000 Interface Modules. In addition,
observe all static safety precautions when handling these modules to prevent
damage from ESD.
1. Unpack the System Monitor by removing it from the shipping box and sliding
the two foam end caps off the unit. (Save the shipping box and packing
materials in the event the System Monitor must be reshipped.)
2. Remove it from the protective plastic bag. Observe all precautions to prevent
damage from Electrostatic Discharge (ESD). (Save the bag in the event the
System Monitor must be reshipped.)
3. Remove the plastic protective cap that covers the connector on the rear of the
System Monitor.
4. Examine it carefully, checking for damage. If any damage exists, DO NOT
install it. Immediately contact Cabletron System.
5. Install the System Monitor Module in the chassis slot marked SM, as shown in
Figure 2-3. Slide the module between the module guide. Take care that the
module slides in straight and properly engages the backplane connectors.
Lock down the plastic tabs at the top and bottom of the module.
If the SmartSwitch 9000-6 Slot chassis has been powered up, the 9C306 System
Monitor illuminates the STATUS LED.
If the STATUS LED is any color other than green, refer to Cabletron Systems
SmartSwitch 9000-6 Slot 9C306 System Monitor UserÕs Guide.
SmartSwitch 9000-6 Slot Chassis Installation
2-7

Advertisement

Table of Contents
loading

This manual is also suitable for:

9c706

Table of Contents