Axis M5525-E User Manual page 22

Ptz network camera
Hide thumbs Also See for M5525-E:
Table of Contents

Advertisement

AXIS M5525-E PTZ Network Camera
Specifications
GND AUDIO IN
AUDIO OUT
GND AUDIO OUT
I/O connector
Use the I/O connector with external devices in combination with, for example, motion detection, event triggering, and alarm
notifications. In addition to the 0 V DC reference point and power (DC output), the I/O connector provides the interface to:
Digital input - For connecting devices that can toggle between an open and closed circuit, for example PIR sensors, door/window
contacts, and glass break detectors.
Digital output - For connecting external devices such as relays and LEDs. Connected devices can be activated by the VAPIX®
Application Programming Interface or from the product's webpage.
6–pin terminal block. See Product overview on page 3 .
Function
0 V DC (-)
DC output
Configurable
(Input or Output)
Power connector
2-pin terminal block for DC power input. Use a Safety Extra Low Voltage (SELV) compliant limited power source (LPS) with either
a rated output power limited to ≤100 W or a rated output current limited to ≤5 A.
Ground audio in
Line audio out
Ground audio out
Pin
Notes
GND
DC ground
12 V
Can be used to power auxiliary equipment.
Note: This pin can only be used as power out.
Digital input – Connect to pin GND to activate, or leave floating
I/O
(unconnected) to deactivate.
1–4
Digital output – Internally connected to pin 1 (DC ground) when
active, and floating (unconnected) when inactive. If used with an
inductive load, e.g. a relay, a diode must be connected in parallel
with the load, for protection against voltage transients.
22
Specifications
0 V DC
12 V DC
Max load = 50 mA
0 to max 30 V DC
0 to max 30 V DC, open drain,
100 mA

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents