Download Print this page

Yale YM Series Installation Instructions Manual page 6

Non handed door closer

Advertisement

YMDC2000 Series
80-9325-0025-010 (06-08)
Sweep "S"
Spring Power Adjustment
(Use 5/16" Socket or Adjustable Wrench for this Adjustment)
The closing force for series YMDC2000 door closers is adjustable
from a size 1 to a size 6, as outlined in ANSI Standard A156.4.
When these series of door closers are installed and adjusted to
conform to ADA reduced opening force requirements (5 lbs max.) for
interior doors, they may not have adequate closing force to reliably
close and latch the door. Power adjustments charted on this page are
recommended where possible, to ensure proper door control.
Arm Placement in Shoe
100 Yale Avenue, Lenoir City, TN 37771 • Product Support Tel 800.438.1951 • Fax 800.338.0965 • www.yalecommercial.com
Yale® is a registered trademark of Yale Security Inc., an ASSA ABLOY Group company. Other products' brand names may be trademarks or registered trademarks of their respective
owners and are mentioned for reference purposes only. These materials are protected under U.S. copyright laws. All contents current at time of publication. Yale Security Inc., an ASSA ABLOY Group
company reserves the right to change availability of any item in this catalog, its design, construction, and/or its materials. Copyright © 2008, Yale Security Inc., an ASSA ABLOY Group company.
An ASSA ABLOY Group brand
(Use allen wrench for these Adjustments)
Latch "L"
Adjust Closing Speed Time to between 3 to 7 seconds from 90°.
!
Use of the door by handicapped, elderly or small children may
require greater closing time.
All rights reserved. Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited.
Backcheck
Adjustment Chart
TYPE
OF
INST.
Regular Arm
Top Jamb
Parallel Arm
Regular Arm
Top Jamb
Parallel Arm
*
21 FULL (360°) TURNS MAXIMUM AVAILABLE
Closer is shipped set at mid range setting = 12 turns
7-1/2 % stronger
or
or
7-1/2 % weaker
— 6 —
CLOSED
Number of Turns Required
MAXIMUM DOOR SIZE
36"
32"
*
(0.85M)
(0.90M)
3
7
6
9
8
4
6
9
By law the Americans with
!
Disabilities Act (ADA) may
require that door closer
installation comply with
accessability guidelines.
42"
48"
(1.00M)
(1.20M)
11
16
19
15
13
17
15
19