Installation sequence
Vitocell without fitted Solar-Divicon
1.
A
C
B
2.
1. Connect heating water flow connec-
tion pipe A to connection D on the
Vitotrans.
2. Connect heating water return con-
nection pipe B to connection E on
the Vitotrans.
Fitting the thermal insulation jacket
!
Please note
The thermal insulation must not
come into contact with naked
flames.
Exercise caution when welding
and brazing.
16
DE F
3.
3. Connect heating water stratification
4. Screw the pipes onto the cylinder
Note
■ 2 people are required for the following
■ Ensure that no fleece remnants enter
(cont.)
4.
connection pipe C to connection
F on the Vitotrans.
connections.
work.
the heating water buffer cylinder
through the cylinder connections.