  • Page 1: Table Of Contents

    10/12/13 LMU-3000 Hardware & Installation Guide - PULS Wiki LMU-3000 Hardware & Installation Guide Contents 1 Introduction 1.1 About This Manual 1.2 About The Reader 1.3 About CalAmp 1.4 About the CalAmp Location Messaging Unit-LMU-3000™ 2 System Overview 2.1 Overview 2.2 Component Descriptions...
  • Page 2: Introduction

    WARRANTY AND REGULATORY INFORMATION. 1 Introduction Welcome to the LMU-3000™ Hardware and Installation Guide. This manual is intended to give you information on the basic setup and installation of the CalAmp LMU-3000™ product(s) including hardware descriptions, environmental specifications, wireless network overviews and device installation.
  • Page 3: About The Reader

    CalAmp delivers cost-effective high quality solutions to a broad array of customers and end markets. CalAmp is the leading supplier of Direct Broadcast Satellite (DBS) outdoor customer premise equipment to the U.S. satellite television market. The Company also provides wireless data communication solutions for the telemetry and asset tracking markets, private wireless networks, public safety communications and critical infrastructure and process control applications.
  • Page 4: System Overview

    ETA, monitoring vehicle and driver status or dispatching the vehicle to its next pick up. These functions, of course, are completely dependent on the capabilities of the vehicle management application. The role of the CalAmp LMU-3000™ is to deliver the location information when and where it is needed.
  • Page 5: Component Descriptions

    Contact the CalAmp sales team for the networks available to the LMU-3000™. 2.2.2 LMU-3000™ The LMU-3000™ is responsible for delivering the location and status information when and where it is needed. Data requests mainly come from the following sources: PEG™...
  • Page 6: Lmu Manager

    LMU Manager is the primary configuration tool in the CalAmp system. It allows access to almost every feature available to the LMU-3000™. Unlike the backend software, it has the option of talking directly to an LMU-3000™ or making a request forwarded by the LM Direct™ server.
  • Page 7: Battery Back-Up Devices

    3.1.2 Battery Back-up devices Please properly dispose of the battery in any of the CalAmp products that utilize one, do not just throw used batteries, replaced batteries, or units containing a back-up battery into the trash. Consult your local waste management facility for proper disposal instructions.
  • Page 8 10/12/13 LMU-3000 Hardware & Installation Guide - PULS Wiki Size 1.7 x 2.5 x 1”, (43 x 64 x 25mm) Weight 1.8 oz, (51 g) Operating Temperature -30° C to 75° C Storage Temperature -40° C to 85° C Humidity 0% to 95% relative humidity, at 50°...
  • Page 9: Lmu-3000™ Connectors

    10/12/13 LMU-3000 Hardware & Installation Guide - PULS Wiki 1800 MHz (Class 1) – 1W 1900 MHz (Class 1) -1 W GPRS Packet Data (UDP) RoHS Compliant 3.2 LMU-3000™ Connectors 3.2.1 Primary Connector Connector on Vehicle side Connector on LMU-3000 side Please note that only 9 out of the 16 connector pins are actually populated on the connector.
  • Page 10: Serial Adapter

    3.3.1 3-Axis Accelerometer Input The LMU-3000™ supports an internal 3 Axis Precision Accelerometer as one of its discreet inputs. When the LMU is moved in any direction, the associated input will be in the High state. If the LMU’s accelerometer https://puls.calamp.com/wiki/LMU-3000_Hardware_%26_Installation_Guide...
  • Page 11: Status Leds

    4 Configuration and Activation This section details how to quickly get an LMU-3000™ provisioned and configured to point at a specific server. It is assumed that a PEG script has already been created and is being managed through LMU Manager or PULS™, the CalAmp Maintenance System.
  • Page 12: Quick Start - General Config

    Specifically, this is pointing the LMU to your LM Direct™ server, either via IP or a URL. This configuration process is accomplished via a series of AT Commands: 1. Power up the LMU-3000™ and connect a serial cable from the LMU to your laptop 2. Open a terminal session to the LMU-3000™...
  • Page 13: Auto Provisioning Of Gsm Or Hspa Lmus

    10/12/13 LMU-3000 Hardware & Installation Guide - PULS Wiki and ppppp is the UDP port number 3. Alternatively if a URL has been set up for your LM Direct™ server, the LMU may be programmed with: ! R P , 2 3 1 9 , 0 , m y U R L . M y C o m p a n y . C o m Where myURL.MyCompany.com is the URL assigned to the server...
  • Page 14 10/12/13 LMU-3000 Hardware & Installation Guide - PULS Wiki o Password: gprs Orange UK (MCC 234, MNC 33, 34) o APN 0 & 1: orangeinternet o Username: user o Password: pass T-Mobile (MCC 310, MNC 16, 20, 21, 22, 23, 24, 25, 26, 27, 31, 58, 66, 80) o APN 0: INTERNET2.VOICESTREAM.COM...
  • Page 15: Activating Gsm Or Hspa Lmu Using At Commands

    4.3 Activating GSM or HSPA LMU using AT Commands Check with the CalAmp Sales team for availability of the LMU-3000™ with GSM or HSPA modems. For a GSM/GPRS operator you will get the LMU in one of two varieties, one with a SIM and one without.
  • Page 16: Accessing The Sim

    1 , 0 , 0 , 3 , 0 , 0 G S M C l a s s : 4.4 Accessing the SIM The following instructions should be used when attempting to access the SIM in a GSM LMU-3000™. https://puls.calamp.com/wiki/LMU-3000_Hardware_%26_Installation_Guide 16/33...
  • Page 17: Activating A Cdma Lmu-3000

    SIM cover. 2. Remove the top-plate to expose the top-side of the LMU-3000™’s main-board. 3. Align the SIM so the contacts are facing up and the notch is facing into the LMU-3000™ 4. Insert the SIM into the LMU.
  • Page 18: Activating A Cdma Lmu-3000™ - Verizon

    ESN. Obviously the first two items are answered by “CalAmp LMU”. The last one is a little misleading. The ESN on the LMU is the CalAmp serial number. The one the operator is interested in is the MSN-D (which they call the decimal ESN). DO NOT give them the CalAmp ESN (i.e. the top one on the label).
  • Page 19: Activating A Cdma Lmu-3000™ - Sprint

    4.5.2 Activating a CDMA LMU-3000™ – Sprint Activating an LMU-3000™ on the Sprint CDMA network is identical to activating on the Verizon network. 1. Power on the LMU-3000™, making sure you can observe the behavior of the Comm LED.
  • Page 20: Activating A Cdma Lmu-3000™ - Bell Mobility

    Verizon Wireless, it requires that the user enter several menu choices in order to complete activation. Unfortunately, this is something the LMU-3000™ does not support, so the activation must be performed manually. Bell Mobility will provide you with a password to gain access to the network (ex: 8889).
  • Page 21: Installing The Lmu

    2. Plug the unit into the OBD2 connector of the vehicle while it is running, and do NOT turn off the ignition. 3. Leave the unit plugged in with vehicle ignition on until the detection process has completed. Vehicle detection status can be checked through SMS over the air or with AT Commands using the CalAmp serial https://puls.calamp.com/wiki/LMU-3000_Hardware_%26_Installation_Guide...
  • Page 22: Installation Verification

    4. Once the vehicle detection has completed the vehicle ignition can then be turned off. 5.3 Installation Verification In many cases it is desirable to verify that an installed LMU-3000™ is working properly. That is, installers should verify that the GPS and communications functions of the LMU-3000™ are working properly before departing the installation site.
  • Page 23: Comm Verification

    If any of the responses return Not-Acquired or Not-Registered (and the APN is correct), the wireless network operator should be contacted for further troubleshooting. Please note that it may take several seconds (or longer) for the LMU-3000™ to communicate with the modem and acquire the wireless network.
  • Page 24: Inbound Verification

    5.3.3 Inbound Verification The last item to verify is that the LMU-3000™ is sending data to the correct server. In general, this is a two- step process that will need the aid of an observer on the back end. That is, a technician will have to be logged in so they can monitor data coming into the backend mapping/vehicle management application.
  • Page 25: Verification Via Sms

    10/12/13 LMU-3000 Hardware & Installation Guide - PULS Wiki The LMU-3000™ will respond with: OK The backend monitor must then be contacted to confirm that they received an Event Report with Event Code 255. Assuming that all three sections have passed, the installation can be considered to be complete.
  • Page 26 10/12/13 LMU-3000 Hardware & Installation Guide - PULS Wiki only the Maintenance socket is ready. A ‘.’ indicates no sockets are ready. o [./a/A]: This field indicates if the LMU has received an Acknowledgement from the Inbound server. This field will be empty if the LMU has never received an ACK. The lower case ‘a’...
  • Page 27: License Agreement

    10/12/13 LMU-3000 Hardware & Installation Guide - PULS Wiki This field details the current state of each of the LMU’s discreet inputs. This field is always 8 characters long. The left most character represents the state of input 7 where the right most represents the state of input 0 (i.e.
  • Page 28 License Certificate. The Software is licensed on a per Developer, and on a per User, per Application basis. In order to preserve and protect its rights under applicable law, CalAmp is not selling you ownership rights to Software or Documentation (owned by or licensed to CalAmp). CalAmp specifically retains title to all CalAmp Software, Documentation and Related Materials and CalAmp licensors retain title to items owned by them.
  • Page 29 May Not (1) Make derivative works including but not limited to translations, adaptations, arrangements or any other alteration (each of which would become the property of CalAmp or its licensors, as applicable) or make copies of the Software or Documentation except as permitted above; (2) Make copies of the Related Materials;...
  • Page 30 Application or make copies of the Application, except one backup copy may be made for each legally obtained copy of the Application, provided that all CalAmp and third party licensor information — including copyright notices — are maintained and possession of the copy is retained in a secure location;...
  • Page 31 Documentation or Related Material(s) shall be replacement of the media, Documentation or Related Material(s) by CalAmp. Each defective item, along with proof of license purchase and date, must be sent in a traceable manner to: CalAmp DataCom Inc., 1401 North Rice Ave. Oxnard, CA 93030.
  • Page 32 20 cm is normally maintained between the transmitter’s antenna and the body of the user or nearby persons. The LMU-3000™ is not designed for or intended to be used in portable applications (within 20 cm of the body of the user) and such uses are strictly prohibited.
  • Page 33 LMU-3000 Hardware & Installation Guide - PULS Wiki To ensure that the LMU-3000™ complies with current FCC regulations limiting both maximum RF output power and human exposure to radio frequency radiation, a separation distance of at least 20 cm must be maintained between the unit’s antenna and the body of the user and any nearby persons at all times and in all...