NOTE: Procedures and techniques that are considered important enough to emphasize. CAUTION: Procedures and techniques which, if not carefully followed, will result in damage to the equipment. WARNING: Procedures and techniques which, if not carefully followed, will expose the user to the risk of fire, serious injury, or death. www.dimplex.com...
OPERATION When the unit is only running with the heater, the (low Figure 1 heat) or the (high heat) icon and the intake temperature will continuously be displayed on the On Screen Display. ! NOTE: The heater may emit a slight, harmless odor C D E F when first used.
2. Correctly install one 3 Volt (CR2032 [longer life] or CR2025) battery in the battery holder. 3. Close the battery cover. Battery must be recycled or disposed of properly. Check with your Local Authority or Retailer for recyc- ling advice in your area Figure 2 www.dimplex.com...
"Click" on the replacement part number to EXPLODED PARTS DIAGRAM view price and availability. www.morelectricheating.com REPLACEMENT PARTS 1. Flicker Motor .....2000500100RP 10.
WIRING DIAGRAM ELEMENT CUTOUT BLOWER MOTOR +T° FLICKER MOTOR 120V / 12V AC/DC ADAPTER AC / DC RELAY BOARD SWITCHBOARD LOGSET ASSEMBLY LOGSET LED ASSEMBLY LED LIGHT ASSEMBLY THERMISTOR DISPLAY-CONTROL BOARD www.dimplex.com...
SWITCHBOARD REPLACEMENT all of the wiring. NOTE: If any tie wraps were removed, replace and en- Tools Required: Phillips Head Screwdriver sure that none of the wires are pinched during reassembly. Flat Head Screwdriver 10. Reassemble in the reverse order as above. CAUTION: If unit was operating prior to servicing allow at least 10 minutes for lights, heating elements and top RELAY BOARD REPLACEMENT...
(Figure 3) 4. Lay the Compact Fireplace on its back. 5. Remove the six screws on the top surface. (Figure 3) 6. Gently open the top panel, laying it on the work sur- www.dimplex.com...
face so that all of the components can easily be seen. 4. Lay the Compact Fireplace on its back. (Figure 4) 5. Gently open the bottom panel, laying it on the work sur- NOTE: The wires are grouped together with tie wraps, face so that all of the components can easily be seen.
9. Properly orient and install the new LED lights and con- Figure 8 nect all of the wiring. Partially 10. Reassemble in the reverse order as above. Reflective Panel Figure 7 Back Ledge Display/ Ember Control Board Support Bracket Rear Front Side Section Edge www.dimplex.com...
DISPLAY/CONTROL BOARD THERMISTOR REPLACEMENT REPLACEMENT Tools Required: Phillips Head Screwdriver Flat Head Screwdriver Tools Required: Phillips Head Screwdriver Needle Nose Pliers Flat Head Screwdriver CAUTION: If unit was operating prior to servicing allow Needle Nose Pliers at least 10 minutes for lights, heating elements and top CAUTION: If unit was operating prior to servicing allow panel to cool off to avoid accidental burning of skin.
Defective display/control board Replace the display/control board 3001430100RP Flame Shudder Defective Flicker Motor Replace Flicker Motor 2000500100RP Light leaking around the log Log set not positioned properly Check log set for proper fit set (if applicable) www.dimplex.com...
Page 13
PROBLEM CAUSE SOLUTION PART NUMBER Heater Heater is not turning off Improper operation Refer to Operation Section Defective switchboard Replace switchboard 3001520100RP Defective thermistor Replace thermistor 3001560100RP Defective relay board Replace the relay board 3001440100RP Defective display/control board Replace the display/control board 3001430100RP Heater is not turning on, but Improper operation...