Operation Manual / TPL69-A10 / -A30 ... TPL77-A10 / -A30
9 Taking out of operation at short notice / 9.4 Blocking the inlets and
outlets
9.4 Blocking the inlets and outlets
9.5 Bypass the turbocharger
© Copyright 2020 . All rights reserved.
CAUTION
Shut off the lubricating oil supply to the turbocharger.
Shut off compressor casing outlet, gas inlet and gas outlet by fitting
u
cover plates.
NOTICE
In this respect, refer to the engine manufacturer's instructions.
CAUTION
Shut off the lubricating oil supply to the turbocharger.
This applies to engines with one turbocharger only:
w
The connections are ready and pipes for the bypass are available.
w
Fit bypass around turbocharger.
u
NOTICE
In this respect, refer to the engine manufacturer's instructions.
HZTL2481_EN
Rev.D
March 2020