Annovi Reverberi AR 115 bp Manual
Hide thumbs Also See for AR 115 bp:

Advertisement

140° F - Max Water Temp
1 1/2" - Suction
1" - Outlet
AR115BP • AR135BP - 550
m
odeL
AR115BP-C
AR115BP-SP
AR115BP-GR3/4
AR135BP-C
AR135BP-SP
AR135BP-GR3/4
AR135BP-GR1
AR115BP-C1000
d
K
iAPHRAgm
iTS
m
d
odeL
eScRiPTion
AR43251
BlueFlex
AR43249
Desmopan
AR43248
NBR
INSTRUCTION MANUAL
- S
RPm
m
gPm
m
L/m
Ax
Ax
28.5
107.9
28.5
107.9
28.5
107.9
33.8
128.0
33.8
128.0
33.8
128.0
33.8
128.0
24.8
94.0
V
K
ALVe
iTS
m
d
odeL
eScRiPTion
AR2370
Valves
AR 115 bp
AR 135 bp
AR 115
-H
T
emi
ydRAuLic
m
PSi
m
in
Ax
Ax
290
20
290
20
290
20
290
20
290
20
290
20
290
20
220
15
o-R
K
ing
iTS
m
d
odeL
eScRiPTion
AR2026
O-Rings
bp
/1000
-d
P
HRee
iAPHRAgm
B
HP P
AR
oweR
5.5
5.5
5.5
6.8
6.8
6.8
6.8
4.2
o
iL
m
odeL
AR64532D
Oil
AR64532D-C Case (6)Oil
umP
w
eigHT
L
.
BS
34.2
34.2
44.0
34.2
34.2
44.0
44.0
34.2

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AR 115 bp and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Annovi Reverberi AR 115 bp

  • Page 1 AR 115 bp AR 135 bp AR 115 /1000 140° F - Max Water Temp 1 1/2” - Suction 1” - Outlet INSTRUCTION MANUAL AR115BP • AR135BP - 550 ydRAuLic HRee iAPHRAgm eigHT HP P odeL oweR AR115BP-C 28.5 107.9 34.2...
  • Page 2 Application Kits Low Pressure AR31058 AR43329 Shaft Kit AR43392: 1 3/8” Male Spline Shaft Pulley Kit AR31058 Pulley 2A 11” Diameter 1" ³⁄₈ universal shaft For AR45, AR80 86,5 For Models: AR70, AR115 & AR135 Hydraulic Motor Flange Kit AR55371 AR55371 AR1514 $281.40...
  • Page 3: Control Units

    Control Units Low Pressure ecm-3 ucm-3 Remote control unit with working pressure regulating valve, complete with Remote control unit with working pressure regulating valve, opening/ glycerin filled pressure gauge with colored dial. closing control lever, anti-drip and glycerin filled pressure gauge with colored dial.
  • Page 4: Important Safety Information

    IMPORTANT SAFETY INFORMATION Intended uses The pump is designed and constructed for incorporation in plants and machinery (spraying machines for the protective treatment of agricultural crops and garden plants). All other uses constitute misuse unless ap- proved by the manufacturer's technical service The pump must be used in a manner appropriate to its technical data (see “Technical Data”), and must not be modified or improperly used.
  • Page 5 Installation diagram (guideline) The following is a simplified illustration of the typical installation layout and is purely a guideline. Control Unit by-pass Tank Agitation Control Unit Intake filter Pump Delivery line filter...
  • Page 6: Installation Instructions

    INSTALLATION INSTRUCTIONS General guidelines on water supply connection To operate correctly, the diaphragm pump must draw in liquids from containers at atmospheric pressure. Do not supply the pump with pressurised liquids. For continuous duty, the pump should not draw in water by gravity from containers with liquid level at heights above 3 m.
  • Page 7 Safety recommendations for handling and lifting Before starting the operations, organise the intended working area so that the materials can be lifted and handled in safety. Unloading, loading, handling and lifting operations must be carried out by skilled, authorised, specifi­ cally trained staff.
  • Page 8 Installation • The crankshaft may turn in either direction. • The water connection with the pump must be made using hoses of suitable diameter, in all case no less than that of the pump fittings, securing them to the fittings using good quality clamps. The intake hose must be coil-reinforced to prevent restrictions.
  • Page 9 Safety recommendations for use Before start-up, the operator must perform the necessary safety checks. In the event of leaks from the pressurized pipes, stop the pump at once and fix the leak. Do not operate the pump above the limits set by the manufacturer to increase its performance. Preliminary checks If the pump has a pressure accumulator, check its level of inflation, see "Checking the inflation pressure".
  • Page 10 Safety recommendations for maintenance Before doing any maintenance work, depressurise the water system and isolate the pump from all en- ergy sources. When the jobs are done, before restarting the pump, check that no tools, rags or other materials have been left close to moving parts or in hazardous zones.
  • Page 11 Table of lubricants The pump is delivered complete with high-performance 30 weight, non-detergent oil suitable for the intended ambient conditions (see "Environmental operating limits"). Inspecting the pump mounting Check that the pump's fixing screws have not become loose. If necessary, tighten them with the driving torque stated in the installation design. Inspecting the connections and pipes - Inspect the connections for leaks.
  • Page 12 Pump Storage It is important to comply with the recommendations for storage in the operator's manual of the machine into which the pump is incorporated. For the pump itself, at the end of pumping operations it is essential to flush out the pump by pumping clean water.
  • Page 13: Troubleshooting

    TROUBLESHOOTING The information provided is intended to provide guidance how to deal with malfunctions which may occur during use. Some of these procedures may be carried out by skilled staff, while others have to be performed at specialised service centres since they require the use of specific equipment as well as detailed knowledge of repair opera­ tions.
  • Page 14 TROUBLESHOOTING Remedy Problem Cause Oil seal on pump Replace the worn oil seal. shaft worn. Oil on pump body or base. Oil pressure inside pump too high. Restore correct oil level in tank. Pump using too much oil (oil flowing from delivery port) or oil Stop the pump at once.
  • Page 15 A.R. NORTH AMERICA A.R. NORTH AMERICA AR 115 bp - AR 135 bp - AR 115 bp/1000 24 - 1 24 - 2 Attention! Assemble with grease between the plate and the membrane 24 - 3 24 - 4 2154700 Air chamber...
  • Page 16 C1000 GR3/4 AR 115 bp - AR 135 bp - AR 115 bp/1000 31701 31702 31709 31704 AR115bp 31705 31706 31708 33142 AR135bp Code Description Code Description Note Note 580013 Pump body 250310 O-ring Ø 36.14x2.62 580150 Manifold 550491 Ring...
  • Page 17 A.R. NORTH AMERICA A.R. NORTH AMERICA AR 1671 : Gear Reduction Per - For: AR 70 bp GR - AR 115 bp GR - AR 135 bp GR Use of engine : B&S Vanguard 6.5 Kohler SH265 - CH270 Honda GC160 - GX160 Subaru E17 - EX21 Ø...

Table of Contents