RRU3260
Installation Guide
Step 5 Label the installed cables according to the instructions in Attaching an L-Shaped Label.
----End

9.9 Opening the Cover Plate of an RRU Cabling Cavity

This section describes the procedure for opening the cover plate of an RRU cabling cavity.
Procedure
Step 1 Wear ESD gloves.
Take proper ESD protection measures, for example, wear ESD gloves, to prevent electrostatic
damage to the boards, modules, or electronic components.
Step 2 Use an M5 Phillips screwdriver to loosen the three screws on the cover plate of the RRU cabling
cavity, and open the cover plate, as shown in
Figure 9-19 Opening the cover plate of the RRU cabling cavity
(1) Cover plate
(4) Cable trough for the power cable
Step 3 Loosen the screws on the clip, and open the clip, as shown
Issue ()
CAUTION
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Figure
9-19.
(2) Cabling cavity
(3) Clip
(5) Waterproof block
(6) Cable trough for the fiber optic cable
9 Installing RRU Cables
Figure
9-20.