Starting Pull Start Engines; Low Oil Level Shutdown System - Generac Power Systems GP3300 Series Owner's Manual

Hide thumbs Also See for GP3300 Series:
Table of Contents

Advertisement

Available languages

Available languages

Starting Pull Start Engines

Recoil Hazard. Recoil could retract unexpectedly.
Kickback could result in death or serious injury.
Equipment and property damage. Disconnect electrical
loads prior to starting or stopping unit. Failure to do so
could result in equipment and property damage.
1. Unplug all electrical loads from the unit's
receptacles before starting engine.
2. Place generator on a level surface.
3. See
Figure
3-2. Open the fuel shut-off
valve (A).
4. See
3-2. Turn engine RUN/STOP
Figure
switch (B) to RUN.
.
D
A
Figure 3-2.Engine Controls
5. See
3-3. Slide engine choke (C) to
Figure
Full CHOKE position (left).
C
Figure 3-3.Choke Position
6. See
3-2. Firmly grasp recoil handle
Figure
(D) and pull slowly until increased resis-
tance is felt. Pull rapidly up and away.
7. When engine starts, move choke knob to
1/2 CHOKE position until engine runs
smoothly, then fully into RUN position. If
engine falters, move choke back to 1/2-
CHOKE
position
smoothly, then to RUN position.
NOTE: If engine fires, but does not continue to
run, move choke lever to Full CHOKE and
repeat starting instructions.
12
WARNING
CAUTION
until
engine
IMPORTANT NOTE: Do not overload gener-
ator or individual panel receptacles. These
outlets are overload protected with push-
to-reset circuit breakers. If amperage rat-
ing of any circuit breaker is exceeded, that
breaker opens and electrical output to that
receptacle is lost. Read
(000183)
Limits
Generator Shut Down
(000136)
Equipment and property damage. Disconnect electrical
loads prior to starting or stopping unit. Failure to do so
could result in equipment and property damage.
1. Shut off all loads and unplug electrical
loads from generator panel receptacles.
2. Let engine run at no-load for several min-
utes to stabilize internal temperatures of
engine and generator.
3. Move RUN/STOP switch to STOP.
4. Close fuel valve.
NOTE: Under normal conditions, close fuel
valve and allow generator to run carburetor
B
bowl out of fuel. For emergencies, switch to
STOP.

Low Oil Level Shutdown System

The engine is equipped with a low oil level
sensor that shuts down the engine automati-
cally when the oil level drops below a speci-
000628
fied level. The engine will not run until the oil
has been filled to the proper level.
If the engine shuts down and there is sufficient
fuel, check engine oil level.
000209
runs
carefully.
CAUTION
Owner's Manual for Portable Generator
Know Generator
(000136)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

006431r1

Table of Contents