2. INSTALLATION

(1) Please have some specialists, who have enough experience for the sewing machine installations,
install the sewing machine.
(2) Please have a Qualified Electrician perform necessary electric wiring.
(3) Please do not operate until the sewing machine is repaired when any damage or fault is found on the
sewing machine at the installation.
(4) Please do not refurbish the sewing machine.

2-1. Installation of the foot switch

Connect the foot switch to the connector CON H.
The foot switch is enclosed in the accessory box.
CON A
CON E
CON F
CON G
CON H
CON J

2-2. Connection of the air tube

Insert the one end of the air tube (8mm Diameter) into the intake air fitting of the filter regulator (No.1)
then, join the other end of the air tube with the suitable air coupling to be adopted with the air supply
source provided in your factory. One of the air couplings (No.2) is enclosed in the accessory box.
<1>
CAUTION
CON A : Operation panel
CON B
CON B : Power supply
CON C : Various solenoid DC power
CON C
CON D : Spindle motor
CON E: Various solenoid
CON D
CON F : Spindle encoder
CON G : X-Y spindle encoder
CON K
CON H : Foot switch
CON J : X-Y spindle stepping motor
CON K : P-F spindle stepping motor
<1>: Intake air fitting
<2>: Air coupling
<2>
- 2 -