Mitsubishi Electric XC-G500-Y Technical Information
Mitsubishi Electric XC-G500-Y Technical Information

Mitsubishi Electric XC-G500-Y Technical Information

Industrial sewing machine control panel

Advertisement

Quick Links

Industrial Sewing Machine
XC-G500-Y
CONTROL PANEL
Thank you for choosing the XC-G500-Y control panel. Please read this user manual carefully prior to usage.
Contents
1. HANDLING INSTRUCTIONS·······························
2. INSTALLATION PROCEDURE ····························
3. SELECTION OF MODE ·······································
4. KEY NAMES AND FUNCTIONS ··························
5. OPERATION PROCEDURES ······························
Straight Lock Stitching ···························································
······································································
6. ERROR DISPLAY ················································

1. HANDLING INSTRUCTIONS

(1) Ensure to always connect the XC-G500-Y control panel to the Limi-Servo XC-G or XC-K Series control
box. The XC-G500-Y control panel cannot be used with other control boxes (XC-E, XC-F, XC-H Series
etc.).
(2) In the interests of safety, always turn OFF the power switch before inserting and removing the connector.
Please be aware that the control panel or control box may be damaged, and the memory contents may be
corrupted if the connector is inserted or removed with the power ON.
(3) Wipe off any machine oil adhering to the control panel with a soft cloth. There is a possibility of color
change, deformation, or peeling of the surface sheet if the control panel is left with oil adhering to it. Please
wipe with a neutral detergent if excessively dirty. Use of solvent will result in color change and deformation,
and therefore should not be used.
2. INSTALLATION PROCEDURE (See Fig. 1.)
(1) Turn OFF the power switch.
(2) Use the installation plate and screws provided, and install using the machine arm back plate tightening
screws and so forth.
(3) Exercise extreme caution to ensure lead wires do not come into contact with the rotating body like the
belt, pulley and so on.
(4) Connect the control panel connector firmly to the control box connector (see Fig. 1).
(5) The pattern display area are lighted when the power is turned ON.
Technical Information
····················································
·····················································
····················································
···················································
··········································
··································
··································
·················································
·····················································
························································
····················································
··············································
(For Limi-Servo XC-G, XC-K Series)
Page
1
1
Installation plate
2
2
5
5
5
6
6
7
7
7
8
9
············
10
11
12
12
13
13
13
- 1 -
XC-G500-Y control panel
Fig. 1 Configuration
E723D873-*(200512)
Power
switch
Connector

Advertisement

Table of Contents
loading

Summary of Contents for Mitsubishi Electric XC-G500-Y

  • Page 1: Table Of Contents

    Industrial Sewing Machine XC-G500-Y CONTROL PANEL Technical Information (For Limi-Servo XC-G, XC-K Series) Thank you for choosing the XC-G500-Y control panel. Please read this user manual carefully prior to usage. Contents Page 1. HANDLING INSTRUCTIONS······························· XC-G500-Y control panel 2. INSTALLATION PROCEDURE ····························...
  • Page 2: Selection Of Mode

    3. SELECTION OF MODE There are 2 kinds of modes in the control panel :Display of setting data for control box like sewing machine direction, sewing machine speed and so on 1) G10 mode (The same display as the XC-G10 control panel) :Display of backtacking data, program input data, teaching input data and so on.
  • Page 3 Pattern number setting key (some of the setting value selection keys) Used to select a pattern. Patterns 1 to 3: Standard lock stitching/fixed-stitch stitching Pattern 4: Continuous backtacking Patterns A to H: Programming/teaching Setting value selection key These other keys are used to change the setting values above the keys. Start backtacking selection key Used to select start backtacking.
  • Page 4 Manual key (used for patterns A to H) Used for manual stitching for the corresponding step during stitching operation. See Using the Manual Key for further details. (Page 7) Needle up key (used for patterns A to H) By pressing this key when the needle is not at the UP position, the sewing machine rotates to the needle UP position and stops.
  • Page 5: Operation Procedures

    5. OPERATION PROCEDURES With the exception of the keys, all key operations are disabled during stitching (during machine operation). (Cannot be changed even by pressing the keys.) Straight Lock Stitching (1) Standard lock stitching (manual stitching) Press pattern number setting key 8 while watching pattern number display area 1 to select from patterns 1 to 3.
  • Page 6: Continuous Backtacking

    Continuous Backtacking While watching pattern number display area 1 , select pattern 4 using pattern selection key 8 . Press the key ( 6 ) to set the number of stitches. LED illuminates and the number of stitches (A, B, C, D) displays at the stitch number display area ( 2 , 3 , 4 , 5 ).
  • Page 7: Using The Automatic Key

    Using the Automatic Key Standard lock When the key is pressed and the LED in the upper left of the key turns stitching OFF, the speed varies based on the amount of pressure applied to the pedal. Fixed-stitch (The sewing machine stops when the pedal is at the neutral position.) stitching Patterns 1 to 3 When the...
  • Page 8: Setting The Pattern By Teaching Input

    Setting the Pattern by Teaching Input Input Fig. 3 is used here as an example to explain pocket stitching. (1) Set the required pattern number from A to H. (2) Press the input key to select input mode. Fig. 3 Pocket stitching (The input LED turns ON.) (3) Ensure that step "1"...
  • Page 9: Setting The Pattern By Program Input

    Step5 Step1 Step2 Setting the Pattern by Program Input Step6 Input Fig. 5 is used here as an example to explain label stitching. (1) Set the required pattern number from A to H. (2) Press the input key to select input mode. Step3 (3) Ensure that step "1"...
  • Page 10: Correcting The Data Programmed For Patterns A To H

    Output The label stitching input at the previous item is used here as an example to explain output. (1) Press the output key ( 20 ) to turn ON the LED in the upper left of the key.The output mode is now selected. (2)Set the pattern number by pressing the pattern number setting key.
  • Page 11: Using The Continuous Key

    2. Inserting Steps To insert a process of 25 stitches between steps 2 and 3 in a Step 4 pattern with a pocket as shown in the diagram on the right, for Step 1 30 stitches example, please proceed as follows. 30 stitches (1) Press the pattern selection keys ( 8 ) to set...
  • Page 12: Using The Function Key

    Using the Function Key function key is enabled at times other than when performing program or teaching input (when the LED is OFF). Turn the key ON to escape from this mode. The display when the key is turned ON will be as follows based on the program mode (C mode) "CNF" function at the control box.
  • Page 13: Using The Program Keys

    Check to ensure that the control box voltage and model (control box model name) / M5 match. Refer to the technical information manual for XC-G or XC-K series for details of errors other than those above. MITSUBISHI ELECTRIC CORPORATION FACTORY AUTOMATION SYSTEM TOKYO BLDG. 2-7-3,Marunouchi Chiyoda-ku Tokyo 100-8310,Japan - 13 -...
  • Page 14 USING THE XC-G500-Y FOR UP COUNTING USING A CERTAIN AMOUNT OF REVOLUTIONS TO TRIGGER THE UP COUNTER 1 TIME WHEN PLUGED IN THE XC-G500-Y WILL DISPLAY THE SAME AS THE CONTROL BOX DID COUNTER FUNCTION: STITCH COUNT TYPE (LOCATED IN THE B-MODE)
  • Page 15 9. USING THE DOWN ARROW KEY FIND THE SETTING P 10. USING THE A, B, C, AND D-KEYS, ENTER THE TARGET COUNT FOR THE UP COUNTER 11. PRESS THE DOWN ARROW AND UP ARROW KEYS TOGETHER TO EXIT THE B-MODE 12.