Front Panel Removal And Installation - Fujitsu AOU18RL Installation Manual

Hide thumbs Also See for AOU18RL:
Table of Contents

Advertisement

FINISHING
(1) Insulate between pipes.
For rear, right, and bottom piping, overlap the connection pipe
heat insulation and indoor unit pipe heat insulation and bind
them with vinyl tape so that there is no gap.
For left and left rear piping, butt the connection pipe heat insula-
tion and indoor unit pipe heat insulation together and bind them
with and vinyl tape so that there is no gap.
For left and left rear piping, wrap the area which accommodates
the rear piping housing section with cloth tape.
For left and left rear piping, bind the connection cord to the top
of the pipe with vinyl tape.
For left and left rear piping, bundle the piping and drain hose
together by wrapping them with cloth tape over the range within
which they fit into the rear piping housing section.
(2) Temporarily fasten the connection cord along the connection pipe
with vinyl tape. (Wrap to about 1/3 the width of the tape from the
bottom of the pipe so that water does not enter.)
(3) Fasten the connection pipe to the outside wall with a saddle, etc.
(4) Fill the gap between the outside wall pipe hole and the pipe with
sealer so that rain water and wind cannot blow in.
(5) Fasten the drain hose to the outside wall, etc.
Fig. 16
(Saddle)
Pipe

FRONT PANEL REMOVAL AND INSTALLATION

THE INTAKE GRILLE REMOVAL
(1) Open the intake grille.
(2) Pull down the knob.
(3) Lift the intake grille upward, until the axle at the top of the intake
grille is removed.
THE INTAKE GRILLE INSTALLATION
(1) The fixing axle of the intake grille is installed on the Panel.
(2) Lay down the intake grille.
THE FRONT PANEL REMOVAL
(1) Remove intake grille (Reference the intake grille removal.)
(2) Remove four screws.
(3) The thumb is hung on the lower part as shown in the figure, and it
pulls to the front, pushing [-] mark , and bottom hooks (two posi-
tion) is removed from wall hook bracket.
(4) The front panel bottom is pulled to the front, and bottom hooks is
removed indoor unit.
(5) The front panel is pulled to the front, raising the upper surface,
and a front panel is removed.
THE FRONT PANEL INSTALLATION
(1) Firstly, fit the lower part of the front panel, and insert top and bot-
tom hooks. (Three top sides, six bottom sides)
(2) Four screws is attached.
(3) The intake grille is attached.
Indoor unit
Bottom hole
(six position)
(Outside wall cap)
(Sealer putty)
(Outdoors)
Wall
Bottom hooks
(six position)
Front panel
Fig. 15
Indoor unit pipe (heat insulation)
Vinyl tape
Connection pipe
(heat insulation)
Pipe
Wrap with
cloth tape
Drain hose Cloth tape
Left piping
Connection cord
Pipe
For connection from the left rear
Wall pipe
Drain hose
View from indoors
Check the following:
GOOD
BAD
Drain hose
Saddle
Lifted up
Fig. 17
Intake grille
Mounting shaft
Bearing
Front panel
Screws
(4 position)
Push
Front panel
Push
[-] mark
Wall hook bracket
Top holes (two sides)
Top hole (center)
Indoor unit
Seal A
Butt connection pipe (heat
insulation) against the indoor
unit pipe (heat insulation)
and wrap with seal A so that
there is no gap.
Drain hose
Connection cord
Connection pipe
BAD
BAD
Wave
End in water
Intake grille
Knob
Front panel
Top hook (center)
Front panel
Top hooks
(two sides)

Advertisement