Technical Data Table - Ariston 200D Instructions For Installation, Use, Maintenance

Heat pump water heater
Table of Contents

Advertisement

TECHNICAL DATA TABLE

DESCRIPTION
Rated tank capacity
Insulation thickness
Type of internal tank protection
Type of corrosion protection
Maximum operating pressure
Diameter of hydraulic connections
Diameter of condensate drainage connection
Diameter of air exhaust/intake pipes
Minimum water hardness
Minimum conductivity of the water
Weight when empty
Weight when filled with water
CYLINDER (EN 12897:2016+A1:2020)
Normal operating pressure
Maximum water supply pressure
Cold connection (feed)
Hot connection (draw off)
Pressure Reducing Valve Set Pressure
Cylinder TPRV
Combination valve PRV
Expansion vessel pre-charge pressure
Operating temperature of not-resetting thermostat
CYLINDER INDIRECT COIL (EN 12897:2016+A1:2020)
Connections
Surface area
Volume coil
Maximum supply pressure
Rating @60°C
Primary flow rate
Pressure drop through coil @15l/min
Primary heating power input
Heating time from 15°C to 60°C
Max water temperature with external integration
HEAT PUMP
Average electrical power consumption
Max. electrical power consumption
Quantity of refrigerant fluid (R134a)
Quantity of fluorinated greenhauses gases (R134a)
Global warning potential (R134a)
Max. pressure of refrigerating circuit (low-pressure side)
Max. pressure of refrigerating circuit (high-pressure side)
Max. water temperature with heat pump
EN 16147 (
A
)
COP (
A
)
Heating time (
A
)
Heating energy consumption (
Max. amount of hot water in a single intake Vmax (
A
Pes (
)
Tapping (
A
)
812/2013 – 814/2013 (
B
)
Qelec (
B
)
ηwh (
B
)
Mixed water at 40°C V40 (
B
)
Temperature setting (
B
)
Annual electricity consuption (average climatic condition) (
Load prifile (
B
)
Indoor sound power level (
C
)
6 /EN
A
)
A
), delivered at 55°C
B
)
Unit
200 D
l
200
mm
Disposable magnesium anode
MPa
II
mm
mm
°F
μS/cm
kg
90
kg
290
bar
3,5
bar
12
¾'' G
¾'' G
bar
3,5
°C/bar
90-95/ 7
bar
6
bar
3,5
°C
--
--
m2
--
m3
--
bar
--
l
--
l/min
--
mbar
--
kW
--
min
--
°C
--
W
W
kg
Tonn. CO
eq.
2
GWP
MPa
MPa
°C
3,10
h:min
03:59
kWh
2,478
l
256
W
21
L
kWh
3,72
%
130,0
l
256
°C
55
kWh/year
790
L
dB(A)
55
250 I
245
≈ 50
Enamelling
0,6
G 3/4 M
14
150-160-200
12
150
123
365
3,5
12
¾'' G
¾'' G
3,5
90-95/ 7
6
3,5
30-70
¾'' G
0,65
0,0047
6
181,9
15
18
9,76
58:40
75
700
900
1,3
1,859
1430
1
2,7
62
3,14
05:24
3,264
333
23
XL
6,04
129,0
333
55
1299
XL
55