  • Page 1 HEAT PUMP WATER HEATER Instructions for installation, use, maintenance 200D - 250I...
  • Page 2: General Safety Instructions

    GENERAL SAFETY INSTRUCTIONS 9. It is mandatory to screw o the water inlet pipe of the unit a safety valve in accordance with national regulations. In countries which have 1. Read the instructions and warning in this enacted EN 1487, the safety group must be manual carefully, they contain important calibrated to a maximum pressure of 0,7 MPa information regarding safe installation, use...
  • Page 3: Safety Regulations

    SAFETY REGULATIONS Personal injury caused by flying splinters or frag- ments, inhalation of dust, knocks, cuts, puncture wounds and abrasions. Key to symbols: Damage to the appliance or surrounding objects Failure to comply with this warning implies the risk of caused by falling splinters, knocks and incisions.
  • Page 4 Product certifications Instructions and technical norms The CE marking of the appliances attests its conformity to the fol- The purchaser pays for the appliance’s installation, which must be lowing EC Directives, of which it satisfies the essential requisites: carried out by qualified personnel only, in conformity with national - 2014/35/EU on electrical safety LVD (EN/IEC 60335-1;...
  • Page 5: Product Description

    PRODUCT DESCRIPTION Main components The floor-standing heat pump water heater consists of a top block containing the heat pump unit and the bottom part of the with the storage tank. There is a control panel with a display on the front part.
  • Page 6: Technical Data Table

    TECHNICAL DATA TABLE DESCRIPTION Unit 200 D 250 I Rated tank capacity Insulation thickness ≈ 50 Type of internal tank protection Enamelling Type of corrosion protection Disposable magnesium anode Maximum operating pressure Diameter of hydraulic connections G 3/4 M Diameter of condensate drainage connection Diameter of air exhaust/intake pipes 150-160-200 Minimum water hardness...
  • Page 7 HEATING ELEMENT Heating element power V / W Check product specification label Max. water temperature with heating element °C Max. current consumption 11,48 POWER SUPPLY Voltage / max. power consumption V / W Check product specification label Frequency Protection rating IPX4 AIR SIDE Standard air flow rate (automatic modulating control)
  • Page 8: Electrical Wiring

    ELECTRICAL WIRING LAMINATION VALVE RESISTANCE PROBE EVAP EBUS CONNECTOR COND BLUE and PURPLE HUMAN MANUAL INTERFACE DISCH CN10 CN14 CN13 CN12 CN12 TANK PROBE CN15 CN10 GROUND CN11 POLE Green CN14 Yellow Orange CN17 CN15 CN13 Brown CN11 FUSE Black HOT GAS VALVE WHITE (1000W)
  • Page 9: Installing The Appliance

    INSTALLING THE APPLIANCE Do not install the product in a room containing an appliance that requires air to function (e.g. an open chamber gas boiler, open-chamber gas water heater, etc.) unless otherwise indicated WARNING! by local law. The product’s safety and performance levels are not The installation and initial start-up of the appliance must be guaranteed in the event of outdoor installation.
  • Page 10: Air Supply Connections

    AIR SUPPLY CONNECTIONS ≥ 500 WARNING! A type of canalization not suitable affects product performance and significantly increases the heating time! Please bear in mind that using air from heated environments may hamper the building’s thermal performance. There is one connection for the air intake and one for the air exhaust ≥...
  • Page 11: Hydraulic Connections

    HYDRAULIC CONNECTIONS WATER CONNECTIONS WARNING: No valves must be fitted between the combination valve and the product. WARNING: No valves must be fitted from the combination valve to expansion vessel or PRV discharge The combination valve can be installed in any orientation. The pipework must be flushed prior to fitting the valve to avoid dam- age to the valve.
  • Page 12: General Guidance

    • OPTION A: A non self resetting mechanical shut-off should be in- GENERAL GUIDANCE stalled on the solar primary flow to the cylinder. The mechanical Current guidance notes do not cover the connection of a solar shut-off should be suitable for use with a solar primary circuit (i.e. thermal circuit to an unvented storage vessel (cylinder).
  • Page 13 250I WITH TYPICAL BOILER CONNCETION 4. Where valves other than a temperature and pressure relief valve TPRV & PRV DISCHARGE from a single unvented hot water system discharge by way of the The discharge from the cylinder TPRV and combination PRV must same manifold that is used by the safety devices, the manifold be plumbed to the tundish and should not be used for any other should be factory fitted as part of the hot water storage system...
  • Page 14 DIAGRAM 1 Typical discharge pipe arrangement Safety device (e.g. temperature relief valve) Metal discharge pipe (D1) from temperature relief valve tundish 600mm maximum Tundish 300mm minimum Discharge pipe (D2) from continuos fall. Discharge below fixed grating see the following table provides alternative discharge points see next paragraphs...
  • Page 15 10. Where a single common discharge pipe serves more than one Termination of discharge pipe system, it should beat least one pipe size larger than the largest 12. The discharge pipe (D2) from the tundish should terminate in a individual discharge pipe (D2) to be connected. safe place where there is no risk to persons in the vicinity of the 11.
  • Page 16: Electrical Connection

    ELECTRICAL CONNECTIONS WARNING! Before you get access to terminals, all supply circuits must be disconnected. IMPORTANT It is forbidden to use multiple outlet sockets, extension cables or Where an appliance is installed in a room containing a bath or show- adaptors.
  • Page 17: Auxiliary Connection

    AUXILIARY CONNECTION The main circuit board on the appliance is fitted with an earth contact for operating purposes only, not for safety purposes. If you have a PV system to be connected or an SG signal available, you can connect a bipolar cable from the inverter or the SG signal Open the cover to access the connection board located on the right, cable (alternatively, not both) to the connection box (secure the cable rear side of the product and carry out the connections according to...
  • Page 18: Bus Connection

    BUS CONNECTION Bus BridgeNet® Connect a cable to the “BUS” connector to manage the heat pump START WIZARD water heater with a single remote control on BUS together with other This product is compatible with Bus BridgeNet®. compatible heat generators. Set the SYSTEM and CASCADE parameters as indicated below for correct installation on BUS during the start phase: •...
  • Page 19: Control Panel

    START-UP INSTRUCTIONS FOR USE Press the " " button to turn the water heater on. The display shows the set temperature and operation mode, while WARNING! the " " symbol and/or " " symbol indicate the operation The installation and initial start-up of the appliance must be per- of the heat pump and/or heating element respective.
  • Page 20: Installer Menu

    The mode can be activated via the installer menu with the P1 parameter. Therefore, each day of the week can be customised one by one • BOOST (button " " ) by selecting the corresponding parameter. both heat pump and heating element are used to reach the set Warning: if the selected time period is too short, the desired tem- temperature in the shortest possible time.
  • Page 21: Anti-Frost Function

    Hysteresis value that allows the heat pump to restart HYST HP after having achieved the target temperature. It can be • P11 PARAMETER - PHOTOVOLTAIC MODE " " set by the installer in the [3 / 12°C] range. If you have a photovoltaic system, you can set the product to op- This parameter gives the capacity of the tank;...
  • Page 22: Default Settings

    DEFAULT SETTINGS The appliance is manufactured with a series of default modes, functions or values, as indicated in the table below: PARAMETER FACTORY DEFAULT SETTING WORKING MODE GREEN DEFAULT SET TEMPERATURE 55 °C MAX. TEMPERATURE SETTABLE WITH THE HEATING ELEMENT 75 °C MINIMUM SETTABLE TEMPERATURE 40 °C...
  • Page 23: Draining The Appliance

    Reset the product by pushing the ON/OFF button twice. If the error persists, Missing communication between Main Board and HMI replace the mainboard-display communication wiring. If WiFi present: - Check cables between motherboard and HMI. - If the error persists, replace the HMI module. Mainboard –...
  • Page 24: Routine Maintenance

    Sorted waste collection for recycling, treatment and environmentally electric heater has to be removed from the Nuos Plus. Only replace compatible scrapping contributes to the prevention of damage to the with Ariston spare parts. environment and promotes reuse/recycling. For more detailed informa- CAUTION: tion on the collection systems available, contact the local waste disposal Removing flange screws (E) will release the stored water.
  • Page 25: Troubleshooting

    TROUBLESHOOTING PROBLEM POSSIBLE CAUSE WHAT TO DO Temperature setting is low Raise the water temperature setting Check for errors on the display and follow the instructions on the “Er- Machine malfunctioning rors” table No electrical connection, wires disconnected or Check the voltage on the power terminals, check the condition of the wires and connections damaged To check the operation of the product start the “Boost”...
  • Page 26: Bench Mark Commissioning Ch Ecklist

    BENCh MARK COMMISSIONING Ch ECKLIST 26 /EN...
  • Page 27: Bench Mark Service Record

    BENCh MARK SERVICE RECORd 27 / EN...
  • Page 28 APPENDIX Ø 150 Ø 200 equivalent equivalent 1m PVC 1m Al Pa MAX 230 Gride 90° PVC 90° Al 28 /EN...
  • Page 29 29 / EN...
  • Page 30 30 /EN...
  • Page 31 31 / EN...
  • Page 32 Manufactured by: Commercialised in UK by: Ariston Thermo SpA Ariston Thermo UK Viale Aristide Merloni, 45 3 Juniper West 60044 Fabriano (AN) Italy Basildon Telefono 0732 6011 SS15 6SJ Fax 0732 602331 www.ariston.com/uk info.it@aristonthermo.com e-mail: info.uk@aristonthermo.com Customer Service: 0333 240 8777...