Ariston 80 L Technical Manual
Ariston 80 L Technical Manual

Ariston 80 L Technical Manual

Heat pump water heater split
Hide thumbs Also See for 80 L:

Advertisement

Technical Manual
H
P
W
H
S
eat
ump
ater
eater -
plit
01/09/2011
Ver.1.2
l
l
l
80
100
110
Because of continuing product improvements, We reserve the right to change specifications without prior notice.
All maintenance operations and interventions should be performed by qualified personnel (i.e. with the necessary requirements
as outlined in the applicable norms in force).

Advertisement

Table of Contents
loading

Summary of Contents for Ariston 80 L

  • Page 1 Technical Manual ater eater - plit 01/09/2011 Ver.1.2 Because of continuing product improvements, We reserve the right to change specifications without prior notice. All maintenance operations and interventions should be performed by qualified personnel (i.e. with the necessary requirements as outlined in the applicable norms in force).
  • Page 2: Table Of Contents

    TABLE OF CONTENTS CONSTRUCTION FEATURES TECHNICAL LABELS ELECTRICAL CONNECTIONS TECHNICAL DATA TABLE OPERATIONAL CURVES EXTERNAL UNIT COMPONENTS • Sensors test table INTERNAL UNIT COMPONENTS HEAT PUMP START UP PROCEDURE FUNCTIONING MODES OPTIONAL FUNCTIONS TROUBLESHOOTING • Displayed faults • Low gas checking •...
  • Page 3: Construction Features

    The split configuration ensures space saving and noise isolation; moreover its layout avoids cooling effect, ventilation constraints and permeability problems. Internal unit construction features MODEL 80 L MODEL 100 L MODEL 110 L 1002 1085 Outlet hot water 1/2”...
  • Page 4: Technical Labels

    External unit construction features Electrical connections housing Gas connections Gas connections housing cover Hole for condensation drain The following accessories are included: Shielded The following accessories are included: Shielded sensor connection cable between units, connection pipe for condensation onnection pipe for condensation water of the external unit, drainage pipe for condensation water rainage pipe for condensation water, wall hole protection, Instruction manual and warranty Instruction manual and warranty...
  • Page 5: Electrical Connections

    ELECTRICAL CONNECTIONS General electrical diagram SYMBOL DESCRIPTION Power supply Electronic filter Interface board Heating element NTC sensor for heating element zone Impressed current anode Ground connection Serial connection board Mainboard Operation condenser Compressor Defrost four ways valve Safety pressure switch hot water NTC sensor evaporator and inlet...
  • Page 6: Technical Data Table

    TECHNICAL DATA TABLE Unit of Description 80 L 100 L 110 L measurement INTERNAL UNIT Rated tank capacity Insulation thickness ≈ 41 ≈ 41 ≈ 41 Type of internal tank protection enamelling Type of corrosion protection titanium impressed current anode + disposable magnesium anode...
  • Page 7: Operational Curves

    OPERATIONAL CURVES Conditions: inlet water temperature 15°C, set water temperature 55°C, air medium humidity 87% - Heating up Energy based on air temperature (EN 255-3). 80 LITRES Mode: GREEN tH-Heating-up time [h:mm:ss] EH-Heating-up energy [kWh] Tair [°C] COPt 4.40.50 1,83 0,456 3.46.17 1,54...
  • Page 8 100 LITRES Mode: GREEN Tair [°C] tH-Heating-up time [h:mm:ss] EH-Heating-up energy [kWh] COPt 6.10.22 2,34 0,504 4.45.40 1,90 0,504 3.26.52 1,53 0,504 2.48.52 1,33 0,504 2.07.37 1,09 0,504 1.55.49 1,03 0,504 Max. amount of hot water in a single intake V40 with water at 55°C 130 l (ratio 1,3) V40 with water at 62°C...
  • Page 9 110 LITRES Mode: GREEN tH-Heating-up time [h:mm:ss] EH-Heating-up energy [kWh] Tair [°C] COPt 6.48.38 2,62 0,504 4.54.47 2,01 0,504 3.41.30 1,64 0,504 2.57.38 1,43 0,504 2.17.03 1,20 0,504 2.10.23 1,16 0,504 Max. amount of hot water in a single intake V40 with water at 55°C 144lt (ratio 1,31) V40 with water at 62°C...
  • Page 10 THERMODYNAMIC CYCLE The heat pump water heater does not directly heat water using electrical energy, but makes a more rational use of the latter to obtain the same result in a more efficient manner, namely by consuming approx. 2/3 less water. The efficiency of a heat pump cycle is measured by the Coefficient of Performance (COP), i.e.
  • Page 11: External Unit Components

    EXTERNAL UNIT COMPONENTS Air and Evaporator sensors 35 µF Compressor electrolytic capacitor 2,5 µF Fan Capacitor 5 poles terminal block 4 way valve electromagnetic coil evaporator 4 way valve thermostatic valve safety pressure switch Gas pipe connection 1/4 “ Gas pipe connection 3/8 “ (includes a “service” connector for vacuum, charge, and pressure check) hermetic rotary compressor Fan support fan motor...
  • Page 12 Compressor (*) Inhales the gas from the evaporator and compresses it in the condenser. Because of the job of compression, the vapor goes out of the compressor with more pressure and strongly overheated. Maintain the conditions of operation of the compressor within the parameters brought in chart, if not respected, not only the performances won't be optimal, but it could present malfunctions and shortening of the life of the compressor.
  • Page 13: Sensors Test Table

    Thermostatic valve (*) Mainly constituted by a body valve, a capillary pipe and a bulb. The body valve is installed on the pipeline of the gas before the evaporator, and the bulb is positioned on the outlet pipe of the evaporator. the valve of lamination has the assignment to reduce the pressure of the R134a.
  • Page 14 Sensors positioning External unit Evaporator sensor Air sensor Internal unit Hot water sensor Heating element zone sensors - 220-240 V - 50 Hz - 10 W - 500 rpm - B Class - IP44 - 3 blades - AC The centrifugal fan is on/off type, 1100 m³/h. Fan start-up capacitor The march capacitor has the purpose to start the fan.
  • Page 15 Four ways valve (*) It is the valve that actives the DEFROST process, it canalizes the fluid overheated coming from the compressor in the evaporator through a capillary, in order to heat the evaporator and melt the ice that clogged it. The valve, is magnetically opened by the spool that receives the electric signal from the electronic card "mainboard."...
  • Page 16: Internal Unit Components

    INTERNAL UNIT COMPONENTS 80-100-110 litres External metal sheet Top plastic cover Water tank Wall bracket Condenser Water pipes (IN-OUT) Gas connections (IN- OUT) Safety valve 8 bar Flange with gasket and Pro-tech titanium anode Magnesium anode (start up anode) Heating element (electrical resistance 1200 W) Wall installation...
  • Page 17 Anti-noise filter It filters possible electric disturbs coming from the mains. Plastics, component sealed with resin auto extinguisher Terminals 5 Faston 6,3x0,8mm Tension 125/250Vac Current 16A (40°C) temperatures interval of operation -25°C/+100°C Dispersion current 2.3mA Condenser (Component not supplied as spare part) The condenser is wrapped around the tank It receives high pressure and temperature vapor from the compressor.
  • Page 18: Heat Pump Start Up Procedure

    PRO-TECH Anode + Magnesium anode The exclusive PROfessional TECh system solution is an anodic anti-corrosion electronic protection system with a modulated current (24 V). It ensures maximum durability in terms of the boiler used in the water heater. The electronic circuit creates a difference in potential between the boiler and the titanium electrode, so that optimal boiler protection is guaranteed, thereby preventing its corrosion.
  • Page 19: Functioning Modes

    FUNCTIONING MODES How to choose the mode Pressing the MODE button is possible to switch between functioning modes in this sequence: How to navigate menu Info and Installer menu The menu “info” (L) regards the information about device status, in the menu “Installer” (P/C) is possible to change time and temperature settings, functioning mode activation.
  • Page 20 AUTO mode This mode is available by default and is the starting working mode set by factory. Recommended for winter to ensure the better comfort. AUTO mode heats the water with a rational use of the heat pump and, only if necessary, of the electrical resistance, according to these two parameters: and Time_W.
  • Page 21 ≤ Case 1: T set-point > Case 2: T set-point...
  • Page 22 BOOST mode This mode is available by default. The BOOST is a temporary mode that shall be set by the user when he has an urgent need of hot water. By activating this mode, the water heater simultaneously uses the heat pump and heating element to reach the desired temperature in the shortest possible time.
  • Page 23 > Case 2: T set-point GREEN mode This mode can be selected only if enabled via installer menu (P4 Parameter ON). The GREEN mode shall be set in order to ensure energy saving; this function is recommended for air temperatures above 0°C during the hours of heating. In this working mode heating is performed with the heat pump only whatever the temperature set by the user or the available electrical power supply time.
  • Page 24 VOYAGE mode This mode can be selected only if enabled via installer menu (P6 Parameter ON). Studied for situations in which users are absent from the appliance’s operating location; this mode allows for programming the number of days of absence, during which the water heater will remain turned off.
  • Page 25 PROGRAM mode: P1/P2/P1+P2 This mode can be selected only if enabled via installer menu (P11 Parameter ON). Activating Program the device allows to reach the set delivery water temperature at the time required, giving priority to heating by heat pump and, if necessary, through the heating element. The final user can set two different programs with two different temperatures and times to be performed separately (P1 or P2) or eventually together (P1+P2).
  • Page 26 > Case 2: T set-point P1 ≤ > Case3: P1+P2 with: set-point P1 set-point P2...
  • Page 27: Optional Functions

    OPTIONAL FUNCTIONS ANTI-LEGIONNAIRE’S DISEASE PROTECTION LEGIONNAIRE’S DISEASE PROTECTION function This function can be enabled/disabled via installer menu (P5 enabled/disabled via installer menu (P5 Parameter: default = OFF). The ANTI-LEGIONNAIRE’S DISEASE PROTECTION LEGIONNAIRE’S DISEASE PROTECTION process avoids the proliferation of dangerous bacteria in the sanitary water tank heating the water until bacteria deadly dangerous bacteria in the sanitary water tank heating the water until bacteria deadly conditions occur.
  • Page 28 CHECK function This function is normally disabled and can be can be enabled via installer menu (C1 Parameter: default = : default = OFF). This function controls the electrical connections made the electrical connections made during installation, switching on the compressor, the fan and the 4-ways valve;...
  • Page 29 TROUBLESHOOTING Displayed faults As soon as a fault occurs, the appliance enters into the fault mode while the display shows flashing signals and visualises the error code. The water heater will continue supplying hot water if the fault affects only one of two the heating units, by activating the heat pump or heating element.
  • Page 30 Error Component Fault cause Fault mode What to check What to do Check the functionality after a main board faulty component → bad data flash temporary power disconnection from If the component is faulty, replace it mains Error Component Fault cause Fault mode What to check What to do...
  • Page 31 Error Component Fault cause Fault mode What to check What to do Check the refrigerant connection • between units and the circuit of Make a gas recharge and check the the external unit using a leak refrigerant connection between units detector.
  • Page 32 Error Component Fault cause Fault mode What to check What to do Check the functionality after a • temporary ON/OFF power disconnection Verify that the resistance between • fan capacitor/motor broken → break terminals is between 200-500 Ω If the component is faulty, replace it Verify that the resistance between •...
  • Page 33: Troubleshooting

    Error Component Fault cause Fault mode What to check What to do evaporator due to ice, leafs, dirt → clogged Visual check of the component Clean the component Check the functionality after a • temporary ON/OFF power disconnection Verify that the resistance between •...
  • Page 34: Malfunctioning

    Malfunctioning Malfunctioning indicates situation of possible customer claim even if any error is displayed on the interface. Malfunctioning Index Info missing Water leakage Insufficient water temperature Long heating time Insufficient water flow Boiling water or steam from the taps Noise increases from the external unit Frequent electrical resistance functioning Bad odor Bad water quality...
  • Page 35 Component Fault cause Fault mode What to check What to do Check if the display shows “off” and if Switch ON the product or Make a Product off there isn’t power from mains proper installation Low temperature set Check the temperature set-point Increase the value Usage of a large amount of hot water Increase the temperature set point...
  • Page 36 Component Fault cause Fault mode What to check What to do Verify with a tester that the resistance faulty component → out of tune between terminals is compliant with If the component is faulty, replace it heating element the “SENSOR TEST TABLE” zone and hot Boiling water sensors...
  • Page 37: Appendix A: Installation Site Inspection

    APPENDIX A: INSTALLATION SITE INSPECTION General rules Are the installation site, the electrical and hydraulic systems to which the appliance must be connected, fully in □ compliance with the regulations in force? Do the installation site have the proper hygienic conditions in relation to the lighting, aeration, solidity? □...
  • Page 38 Is the place of installation in compliance with the regulation in force and with the IP protection grade? □ Does the installation site disposes a main electrical source 220-240 V 50 Hz single phase? Is easy to access for installation □...
  • Page 39: Available Installation Accessories

    Other materials (not supplied): □ 5 pin power cable (4 x 0,75 mm² + ground cable) long enough for the connection between internal and external units 5 pin power cable (4 x 0,75 mm² + ground cable) long enough for the connection between internal and external units 5 pin power cable (4 x 0,75 mm²...

This manual is also suitable for: