ES – Errored Seconds displays the number of seconds in which one or more
errors occurred
EFS – Error Free Seconds displays the number of total seconds that a test has
run error free
%EFS – Percent Error Free Seconds displays the current ratio of EFS to total
test seconds
SES – Severely Errored Seconds displays the total number of seconds with an
error rate >= 1.0e-3
%SES - Percent Severely Errored Seconds displays the current ratio of SES to
total test seconds
To turn a BERT pattern off tap on the selected BERT pattern (e.g. 2047) and select
"BERT Off" at the top

Receiving a Call

Before receiving an incoming call make sure "LINK Active" is displayed in the current
state window on the bottom left of the LCD If NO LINK then check DS1 Layer-1 using
the DS1-B test application and check for OOF and signal/level.
When the test set receives an incoming call in the call progress window it displays
RING: the type# and call (Voice, Data, Audio), the B-Channel and Caller ID infor-
mation. To answer the incoming calls tap the Answer button (only visible when call is
pending) on the top of the screen.
You should see Connected on the status window. If the incoming call is a VOICE call,
connect a butt-set or any analog phone to the RJ11 port on the front panel and from
the main menu (press Home key for main menu) select Sig-TIMS app, tap the 4-wire
TIMS mode followed by ISDN B Channel. Tap the Home key followed by the PRI
mode, the voice circuitry is now connected to the RJ11 jack. Note you need only do
this once for any voice call.
If the incoming call is a DATA call press the Answer button (note Connected) and se-
lect a BERT pattern (2047, 511, ALT, 1's) from the BERT pull-down menu (2047 most
common). The test set will display SYNC if it receives the BERT pattern it is sending
along with 0 Bit Errors.
To insert a Bit Error, Tap the Inject Error button. Tap the Clear (button to right of
Count) to restart the BERT and Clear any Bit Errors. Tap the COUNT button to change
the display from Bit Errors (default) to the display desired.

Terminate Call

The Hang Up and Answer button will only be visible when there is a call pending or
established To hang up, tap the "Hang up" button and select the call (by ID#) to dis-