Page 1
Nucleus® CP910 and CP920 Sound Processor Hybrid Hearing Supplement Patient Information FDA approved for use with the Hybrid L24 (CI24REH) Implant...
Page 2
CP910 Sound Processor with Standard Rechargeable Battery Module Coil Coil magnet Microphones and microphone protectors Indicator light Upper button Coil cable Lower button CP910 Earhook Processing unit Accessory Serial number socket Standard rechargeable battery module CP920 Sound Processor with Acoustic Component with Compact Rechargeable Battery Module Coil Coil magnet...
Page 3
This guide is for recipients of the Cochlear ™ NOTE Nucleus Hybrid L24 Cochlear Implant. It ® Please refer to the booklet Important providesinformation about using an acoustic Information: Warnings, Precautions and Electromagnetic Compatibility for important component with your sound procesor for information that applies to cochlear Hybrid Hearing.
• a tamper resistant battery module • a closed accessory socket • a coil and coil cable • no acoustic component. • a closed accessory socket • an acoustic component worn in the ear. COCHLEAR NUCLEUS 6 • HYBRID HEARING SUPPLEMENT...
The acoustic component If your sound processor is programmed for use in Hybrid mode, you can wear it with an acoustic component. Wear your acoustic component Hold the coil in one hand and place the processor on your ear with the other. Place the coil on your head.
Page 7
Talk to your clinician before replacing: Remove the battery module from the processing unit by twisting the two parts as shown. Locate the opening under the earhook. COCHLEAR NUCLEUS 6 • HYBRID HEARING SUPPLEMENT...
Page 8
Screwdriver into the hole. Carefully push and twist the screwdriver until the speaker unit cable disconnects. Re-attach the battery module. Press firmly on top of the Cochlear EAC200 Series Earhook with your thumb to click it off the sound processor.
Page 9
Insert a new processing unit plug into the speaker unit cable socket. Make sure the plug goes all the way in. Click the standard earhook into place. COCHLEAR NUCLEUS 6 • HYBRID HEARING SUPPLEMENT...
Page 10
Attach your acoustic component Press firmly on the top of the standard earhook with your thumb to click it off the processor. Insert the Cochlear™ EAC200 Series Screwdriver into the hole in the processor unit plug. Use the screwdriver to carefully remove the plug.
Page 11
It should click securely into place. If necessary, carefully push it until you feel the click. Pull gently on the cable to check that it’s securely in place. COCHLEAR NUCLEUS 6 • HYBRID HEARING SUPPLEMENT...
Do not drop the acoustic System filters ONLY. component. Do not twist the speaker unit cable. RITE Power Moulds can use either Cochlear Keep the speaker unit away from the coil magnet. EAC200 Series NoWax Wax Management System or WaxStop filters.
Page 14
Replace Power Domes Pull the dome off using your fingernails if necessary and discard. Push the new dome directly onto the speaker unit. Click it securely into place. Replace Plus Domes Follow the directions for replacing Power Domes and add the following step: When fitting a Plus Dome, the outer sleeve should face down.
Page 15
Power and Plus Domes must be worn with a WaxStop filter in the speaker unit. Remove a WaxStop tool from its shell. One end of the tool has a new filter and the other has a removal tool. Insert the removal tool into the existing wax filter. COCHLEAR NUCLEUS 6 • HYBRID HEARING SUPPLEMENT...
Page 16
Pull the used filter out slowly, keeping the tool straight. Flip the tool and push the new filter into the sound outlet. Carefully pull the tool free and dispose of the used tool and filter.
Page 17
• Do not push the volume too high for comfort in case a loud noise occurs nearby. • Do not place the device or accessories inside any part of your body (e.g. nose, mouth). COCHLEAR NUCLEUS 6 • HYBRID HEARING SUPPLEMENT...
Acoustic component • If the Power Dome or Plus Dome is not securely attached to your acoustic component, it could fall off in your ear • Refit and replace domes regularly to canal. If this happens, see your medical ensure optimal fitting and retention. practitioner.
Page 19
• Battery lifespan means the total • Processor covers are made of polystyrene number of charge cycles a rechargeable and polycarbonate. battery will last before the battery life degrades to 80% of its original fully- charged capacity. COCHLEAR NUCLEUS 6 • HYBRID HEARING SUPPLEMENT...