7.2. Removal of the Slot block
Caution:
To remove P.C.B., wait 1 minute after power was off for discharge from
electrolysis capacitors.
1. Remove the couplers (J1, J2, J3, J4, J5, J6, J7, J8, J10, J15).
2. Release the cable from the clampers at left side of the slot block.
3. Unscrew the screws (×4 ) and remove the slot block.
13