Lighting Instructions - B+S Verro Series Installation And User Instructions Manual

Hide thumbs Also See for Verro Series:
Table of Contents

Advertisement

Lighting Instructions;

Flame Failure Gas Valve;
1.
Turn main gas knob 30º anti-clockwise and push to start pilot gas
flow.
2.
Push the Piezo button adjacent to the gas valve knob located on the
control panel to light the pilot.
3.
When pilot is alight, hold down main gas knob for approximately 15
seconds, or until thermocouple has warmed sufficiently to maintain
flame.
4.
Once pilot flame is established, rotate main gas knob a further 60º
anti-clockwise to maximum, or a further 120º to minimum.
5.
If pilot flame shuts off prior to establishing, repeat steps 1-4 until
thermocouple has warmed sufficiently to maintain gas flow.
Shut Down Procedure;
1.
Rotate main gas valve knob clockwise to off position.
2.
Observe pilot and main burner flames are extinguished.
9
"OFF" Position
"PILOT" Position (on units tted with pilot and ame failure)
"HIGH" Position
"LOW" Position
PILOT
MAX
OFF POSITION
MIN
© B&S Commercial Kitchens Pty Ltd 2016