5. Bin Control Selector (S1 dip switch 7)

The appliance is factory set for infrared sensor bin control operation. No adjustment is
required. In the factory default position (S1 dip switch 7 in the on position), the gear motor
delay after the upper float switch closes is 30 sec. WARNING! Do not place S1 dip
switch 7 in the off position. This could lead to icemaker movement or ice overflow.
S1 Dip Switch
Setting
No. 7
OFF
BC2 (mechanical stand-alone) (Standard Ice Storage Bins Only) 5 seconds
BC1 (infrared sensor) Stand-Alone and
ON
BC1 (infrared sensor) with BC2 (mechanical backup)

6. BC2 (Mechanical Backup) Shutdown Delay (S1 dip switch 8)

Not available when S1 dip switch 7 is on. Factory set for normal operation. No adjustment
is required. This appliance does not utilize a mechanical bin control.

7. Shutdown Sequence (S1 Dip Switch 9)

Factory set for optimum performance. Do not adjust.
S1 Dip Switch
Setting
No. 9
Slow timing (90s after Mechanical Bin Control delay is satisfied, the COMP shuts
OFF
down; after an additional 60s, the GM shuts down)
Fast timing (after Mechanical Bin Control delay is satisfied both COMP & GM shuts
ON
down at the same time)

8. Alarm Selection (S1 Dip Switch 10)

Factory set for optimum performance. Do not adjust.
S1 Dip Switch Setting
Bin Control Application
S1 Dip Switch Setting
No. 8
OFF
ON
No. 10
OFF
Beep
ON
No Beep, power LED blinks with the number of error code
Mechanical Bin Control
Shutdown Delay
0.25 Seconds
6.7 Seconds
Shutdown Sequence
Shutdown Sequence
41
Gear Motor Delay
30 seconds