• The icemaker requires an independent power supply of proper capacity. See the
nameplate for electrical specifications. Failure to use an independent power supply
of proper capacity can result in a tripped breaker, blown fuse, damage to existing
wiring, or component failure. This could lead to heat generation or fire.
• THE ICEMAKER MUST BE GROUNDED. The icemaker is equipped with a
NEMA 5-15 three-prong grounding plug
hazards. It must be plugged into a properly grounded, independent 3-prong wall
outlet. If the outlet is a 2-prong outlet, it is your personal responsibility to have
a qualified electrician replace it with a properly grounded, independent 3-prong
wall outlet. Do not remove the ground prong from the power cord and do not use
an adapter plug. Failure to properly ground the icemaker could result in death or
serious injury.
• Do not use an extension cord.
• Do not use an icemaker with a damaged power cord. The power cord should not be
altered, jerked, bundled, weighed down, pinched, or tangled. Such actions could
result in electric shock or fire. To unplug the icemaker, be sure to pull the plug, not
the cord, and do not jerk the cord.
• Do not place fingers or any other objects into the ice discharge opening.
SRC
• The remote condensing unit requires an independent power supply of proper
capacity. See the nameplate for electrical specifications. Failure to use an
independent power supply of proper capacity can result in a tripped breaker, blown
fuse, damage to existing wiring, or component failure. This could lead to heat
generation or fire.
• Electrical connection must be hard-wired to the remote condensing unit and must
meet national, state, and local electrical code requirements. Failure to meet these
code requirements could result in death, electric shock, serious injury, fire, or
damage.
• THE REMOTE CONDENSER UNIT MUST BE GROUNDED. The power supply and
ground connection to the remote condenser unit are supplied from the icemaker.
Failure to properly ground the remote condenser unit could result in death or
serious injury.
• Wire routing (conduit) and disconnect (if required) must meet national, state, and
local electrical code requirements. Failure to meet these code requirements could
result in death, electric shock, serious injury, fire, or damage.
WARNING, continued
to reduce the risk of potential shock
6