Axis P8815-2 User Manual page 15

3d people counter
Hide thumbs Also See for P8815-2:
Table of Contents

Advertisement

AXIS People Counter
Configure the application
Reverse in/out direction
To calculate the occupancy levels of the two adjacent rooms connected by the same secondary camera, you must select Reverse
In/Out direction in one of the primary cameras. This overrides the Direction in setting made in the secondary camera, but only
for this occupancy area. In other words, this ensures that people walking out from the first room, are considered walking in
to the second room and vice versa.
1
Primary camera, room 1
2
Secondary camera
3
Primary camera, room 2
Full-day analysis
The full-day analysis is selected by default.
Full-day analysis means that the occupancy that has been calculated during the day is slightly modified after closing. This is
because when the data for a complete day is gathered, more details about that day is available and the application can give a more
precise estimation of the occupancy during that day. The occupancy application automatically detects when the occupancy area is
open or closed by observing the flow of visitors.
Consequently, full-day analysis also means that the primary camera only sends statistical data once a day to AXIS Store Data Manager.
Smart and naive occupancy mode
You can run the occupancy estimation in either smart or naive mode. The functionality is developed for smart occupancy mode, but
at locations where traffic and average visiting time are not steady, naive occupancy can still provide additional value.
Smart occupancy mode
The smart occupancy means that the application analyses frequency of passages and in turn calculates an average visiting time,
which is then used to filter away counting errors that accumulate throughout the day. The output is an estimated occupancy and
average visiting time at any given time as well as a corrected full day analysis at the end of the day.