QUICK REFERENCE GUIDE / OPERATIONAL SUMMARY

ALARM AUDIBLE & VISUAL SIGNALS
CONDITION
New - Out
of Package
DC Power is
Present
Test/Silence
Button Has
2 second pause
Been Pressed
Originating
2 second pause,
Smoke Alarm
Nuisance
Alarm
2 second pause,
Alarm has
Sensed Smoke
2 second pause,
Alarm has
Previously
Sensed Smoke
Alarm needs to
be reset due
to varying
conditions/
previous alarms
Low Battery
approx every
60 seconds
Product
End-of-Service
approx every
Life Notification
60 seconds
Sensor Trouble
3 Chirps approx
Signal
every 60 seconds
Alarm Reset - Press and Hold the Test/Silence button for approximately 10-15 seconds and release. This will clear the Silence
Feature and Alarm Origination.
THIS PRODUCT CONFORMS TO UL STANDARD 217 FOR SAFETY
HORN
RED LED
Silent
Silent
Blinks On once
approx every
2 minutes
3 beeps,
Blinks On in sync
with Horn
3 Beeps,
Blinks On in sync
with Horn
Repeat
3 Beeps,
Blinks On in sync
with Horn
Repeat
3 Beeps,
Blinks On in sync
with Horn
Repeat
Silent
Blinks On once
(alarmed
approx every
previously)
2 minutes
(normal operation
mode) or Blinks On
once approx every
10 seconds
(silence mode)
Silent
Blinks On once
approx every
2 minutes
(normal operation
mode) or Blinks On
once approx every
10 seconds
(silence mode)
2 chirps
Blinks On once
approx every
2 minutes
2 chirps
Blinks On once
approx every
2 minutes
Blinks on approx.
every 2 minutes
Off
To activate the alarm, remove the pull tab. The alarm will sound
one long beep to confirm it is powered up. Press the Test/Silence
button. Test the alarm following installation and weekly thereafter.
The built-in test switch accurately tests the alarm operation as
required by ANSI/UL217 Standards for Safety. If, at any time,
you test the alarm and it does not perform as described, replace
it immediately.
The alarm is operating properly.
Test the alarm following installation and weekly thereafter.
The built-in test switch accurately tests the alarm operation
as required by ANSI/UL217 Standards for Safety. If, at any
time, the alarm does not perform as de scribed during the
test, replace it immediately.
If hazard is identified, please take all precautions if an alarm
sounds by calling an Emergency Service and getting out of
the home.
If there is no hazard present, verify the alarm is mounted
in the correct location (see User's Manual, "AVOID THESE
LOCATIONS" section). Reset alarm as instructed below.
Silence Feature is activated by pressing and releasing the Test/
Silence button on the initiating alarm while in alarm condition.
Silence mode will last for approx 10 minutes with the red LED
blinking once approx. every 10 seconds.
QUICK FIND
will allow you to locate the originating alarm (once the alarms
have stopped sounding). To initiate QUICK FIND
Test/Silence button on any alarm. After releasing the button,
the originating alarm will continue to sound for approx 60
seconds. It is necessary to test each alarm to determine the
originating alarm.
To reset the alarm, hold the Test/Silence button for approx
10-15 seconds and release. This will clear Alarm Origination.
Reset alarm after every alarm event.
Deactivate alarm (see User's Manual "ALARM DEACTIVATION"
section). Replace alarm immediately.
Deactivate alarm (see "ALARM DEACTIVATION" section in
User's Manual). Replace alarm immediately.
Reset the alarm. If this does not clear the problem,
replace alarm.
Page 9