Universal Security Instruments MP117 Instructions Manual

Universal Security Instruments MP117 Instructions Manual

Smoke & fire alarm with silence and alarm origination feature

Advertisement

Quick Links

SECURITY INSTRUMENTS, INC.
SMOKE & FIRE ALARM WITH SILENCE FEATURE
Smoke Alarm Limitations and Functions ................................. 2
Recommended Location of Alarms ......................................... 3
Avoid These Locations ........................................................... 4
Early Warning ......................................................................... 4
Installation Instructions ........................................................... 4
Electrical Shock Hazard ......................................................... 4
Locking/Tamper Feature ......................................................... 4
Wiring Instructions .................................................................. 5
Operation, Testing & Maintenance .......................................... 6
Cautions/Warnings ................................................................. 7
Backup Battery Replacement ................................................. 7
Develop and Practice a Plan of Escape .................................. 8
Operational Summary ............................................................. 9
Warranty ................................................................. Back Cover
MODEL MP117, MP117L
MODEL MP118, MP118L
AND ALARM ORIGINATION FEATURE
READ ALL INSTRUCTIONS

Table of Contents:

®
Page #

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MP117 and is the answer not in the manual?

Questions and answers

Summary of Contents for Universal Security Instruments MP117

  • Page 1: Table Of Contents

    ® Cautions/Warnings ... 7 Backup Battery Replacement ... 7 Develop and Practice a Plan of Escape ... 8 Operational Summary ... 9 Warranty ... Back Cover MODEL MP117, MP117L MODEL MP118, MP118L READ ALL INSTRUCTIONS Table of Contents: Page #...
  • Page 2: Smoke Alarm Limitations And Functions

    SMOKE ALARM LIMITATIONS AND FUNCTIONS There are three basic smoke alarm types: IoPhic , Ionization and Photoelectric.   IoPhic is an ionization alarm containing a patent-pending Universal Smoke Sensing Technology.   IoPhic alarms are very effective at detecting fast flaming fires and also respond very quickly to slow smoldering fires - up to 87% faster than the maximum allowable alarm limit (UL217 Smoldering Smoke Test on 5/26/2010, Underwriters Laboratories Project #09CA38078).
  • Page 3: Recommended Location Of Alarms

    RECOMMENDED LOCATION OF ALARMS • Locate the first smoke alarm in the immediate area of the bedrooms. Try to protect the escape route as the bedrooms are usually farthest from an exit. If more than one sleeping area exists, locate additional smoke alarms in each sleeping area. If a hall is more than 40 feet (12 meters) long, install a smoke alarm at each end.
  • Page 4: Avoid These Locations

    • the garage – products of combustion are produced when you start your vehicle. • near appliances or areas where normal combustion regularly occurs (kitchens, near furnaces, gas hot water heaters). Use smoke alarms with photoelectric sensors or smoke alarms with Silence Feature for these areas.
  • Page 5: Wiring Instructions

    Insert the pin into the hole for the feature you are activating. Refer to the diagram below for correct placement. INSERT ALARM LOCKING PIN HERE TO DEACTIVATE THE LOCKING FEATURES: To remove the smoke alarm for cleaning or servicing or to replace the battery, you must first remove the appropriate locking pin, if it has been installed. Turn off AC power to the circuit.
  • Page 6: Operation, Testing & Maintenance

    The yellow wire is used only for multiple station operations with USI ELECTRIC or UNIVERSAL Model alarms only. Connecting this yellow wire to any other circuits may result in damage and alarm malfunction. When alarms are interconnected, all alarms must be powered from a single AC branch circuit.
  • Page 7: Cautions/Warnings

    ® RESET: To reset the QUICK FIND Alarm Origination condition, press and hold the Test button on any alarm for at least 10 seconds and then release. Reset after each alarm. The reset feature will reset all interconnected units. TROUBLE/SERVICE ALARM: If the smoke alarm beeps 3 times approx. every 40 seconds after the red LED flashes and cannot be restored to normal operation, the smoke alarm should be replaced.immediately.
  • Page 8: Develop And Practice A Plan Of Escape

    LITHIUM Battery Models only - The LITHUM battery is warranted to last for 10 years under normal operating conditions. Replace the battery with only LITHIUM type: (ULTRALIFE: U9VL-J or Ultralife U9VL-J-P). OPTIONAL BATTERY DRAWER TAMPER LOCKING PIN: To make your battery drawer tamper resistant, a locking pin has been provided (breakaway part on mounting bracket).
  • Page 9: Operational Summary

    -- Reorient or relocate the receiving antenna. -- Increase the separation between the equipment and receiver. -- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -- Consult the dealer or an experienced radio/TV technician for help. CAUTION (AS REQUIRED BY THE CALIFORNIA STATE FIRE MARSHAL) "Early warning fire detection is best achieved by the installation of fire detection equipment in all rooms and areas of the household as follows.
  • Page 10: Warranty

    USI ELECTRIC, INC./UNIVERSAL SECURITY INSTRUMENTS, INC. ("USI") warrants your USI product to be free from defects in material and workmanship for a period of ten (10) years from the date of purchase. This warranty shall not apply to any batteries used in the product or to any damage which may be caused by such batteries.