ID146 WiFiFault
WIFI failure
BluetoothFa
ID147
Bluetooth failure
ult
ID148 RTCFault
RTCClock failure
CommEEPR
Communication BOARD
ID149
OMFault
EEPROM error
CommEEPR
Communication BOARD
ID150
OMFault
FLASH error
ID151 Reserved
Reserved
SafetyVerFa
ID152
Satety Version is Fault
ult
SciCommLo
SCI communication(DC
ID153
se(DC)
side)
SciCommLo
SCI communication(AC
ID154
se(AC)
side)
SciCommLo
SCI communication(DC
ID155
se(Fuse)
current combined side)
SoftVerErro
Inconsistent software
ID156
r
version
ID157 Reserved
Reserved
ID158 Reserved
Reserved
ForceShutd
ID161
ForceShutdown
own
RemoteShu
ID162
RemoteShutdown
tdown
Drms0Shutd
ID163
Drms0 shunt down
own
RemoteDer
ID165
RemoteDerating
ating
SOFAR 3.3~12KTLX-G3
There are internal faults of inverter, turn OFF the
"DC switch", wait for 5 minutes, then turn ON the
"DC switch". Check whether the fault is rectified. If
no, please contact technical support.
Remote control enables. If it is not controlled by
yourself, please disconnect the DC switch of the
inverter, wait for 5 minutes, and then turn on the
DC switch. Observe whether the fault has been
eliminated after the inverter is restarted. If not,
please contact the customer service of
SOFARSOLAR.
Inverter shows ID83 when remote derating. If no
one operate this function, please check the
connection (I/O) according to chapter 4.5