120 USG / 450 ltr Tank Installation
Temperature sensor installation (when using a Vitotronic 200 / 300 or Vitodens 200)
The primary DHW tank temperature sensor is included in the boiler control unit package.
2.
3.
Fig. 13
Checking anode connection and fitting lid
1.
2.
Fig. 14
1.
4.
A
B
1.
(continued)
Set-up and Connections
1. Remove sensor mounting hardware
from sensor well.
2. Position the temperature sensor on
the outside of the location spring (not
in the groove), so that it is flush with
the front of the spring.
3. Attach sensor cable to clip.
IMPORTANT
Never wrap insulating tape around the
sensor.
4. Insert the sensor mounting hardware
with the sensor until it bottoms out
inside the lower sensor well.
Note:
When using a Vitotronic 100 boiler
control, refer to page 14 for aquastat
installation.
1.Ensure the grounding wire
properly secured to magnesium
anode
.
Magnesium anode
Grounding wire cable
is
13