Figure 37. Intermittent Pilot Ignition (IPI) Wiring Diagram
For Intermittent Pilot Ignition (IPI) Wiring
Appliance Requirements
This appliance requires that 110-120 VAC be wired to the
junction box. Maintain correct polarity when wiring the junc-
tion box.
Operation using Battery Power
This fireplace has an optional battery operation. The sys-
tem is fully functional with the use of two "D" size batteries
without ordinary 110-120 VAC power.
Wiring to the battery pack should be left disconnected in
order to conserve battery life. In the case of a loss of power,
simply connect red and black wire leads to activate battery
power (connect red to red, black to black). The fireplace
can be used as necessary. Once power (110 VAC) is re-
stored, disconnect red and black wire leads to extend bat-
tery life.
JUNCTION BOX
120 VAC
JUNCTION BOX
120 VAC
REM
FAN
WALL SWITCH
FAN OUTLET RECEPTACLE
(NO FAN OPTION)
OPTIONAL
FLAME SPARKER/
REMOTE
SENSOR
OPTIONAL
BATTERY
BACK-UP
LOW VOLTAGE
SEE NOTE 1
REMOTE
CONTROL
HOT
TRANSFORMER
3 VAC
FAN
BRN
BRN
OPTIONAL
BATTERY BACKUP
Optional Accessories
Optional fan and remote control kits require that 110-120
VAC be wired to the fireplace junction box.
Wall Switch
Position the wall switch in the desired position on a wall.
Run 16 A.W.G. minimum Romex wire a maximum of 25
feet and connect it to the fireplace ON/OFF switch pigtails.
CAUTION: LABEL ALL WIRES PRIOR TO DISCONNEC-
TION WHEN SERVICING CONTROLS. WIRING ERRORS
CAN CAUSE IMPROPER AND DANGEROUS OPERATION.
VERIFY PROPER OPERATION AFTER SERVICING.
38
INTERMITTENT PILOT IGNITOR
IGNITION MODULE 3 VAC
I
S
ORG
WHT
GROUND TO
FIREPLACE
CHASSIS
GRN
VALVE