Heat-N-Glo SL-950TR-C Installer's Manual page 21

Table of Contents

Advertisement

V 1
H 1
Use SL D-Series
components only.
NOTE: There MUST be a 25% reduction in
total H when using flex vent except when
using the simple up and out installation
(see Figure 9).
Figure 19. Venting with three 90° elbows - TR-C Models
VENTING WITH THREE (3) 90
MODEL SL-550TR-C
V (MIN.)
H + H
(MAX.)
1
o
90
Elbow on Top
2.5 FT (863mm)
1 FT (305mm)
3 FT (914mm)
2 FT (610mm)
4 FT (1.22m)
3 FT (914mm)
6 FT (1.86m)
4 FT (1.22m)
8 FT (2.48m)
5 FT (1.52m)
16 FT (4.8m)
H + H
MAX. = 16 FT (4.8m)
1
VENTING WITH THREE (3) 90
MODEL SL-550TR-C
V (MIN.)
H + H
(MAX.)
1
90
o
Elbow on Top
2.5 FT (863mm)
1 FT (305mm)
2.5 FT (863mm)
2 FT (610mm)
4 FT (1.22m)
3 FT (914mm)
6 FT (1.86m)
4 FT (1.22m)
8 FT (2.48m)
5 FT (1.52m)
16 FT (4.8m)
H + H
MAX. = 16 FT (4.8m)
1
27
o
ELBOWS
NATURAL GAS
MODEL SL-750TR-C MODEL SL-950TR-C
H + H
(MAX.)
H + H
1
2.5 FT (863mm)
2 FT (610mm)
3 FT (914mm)
3 FT (914mm)
4 FT (1.22m)
4 FT (1.22m)
6 FT (1.86m)
6 FT (1.86m)
8 FT (2.48m)
8 FT (2.48m)
16 FT (4.8m)
16 FT (4.8m)
V + V
+ H + H
MAX. = 40 FT (12.2m)
1
1
o
ELBOWS
PROPANE
MODEL SL-750TR-C MODEL SL-950TR-C
H + H
(MAX.)
H + H
1
NOT ALLOWED
NOT ALLOWED
2 FT (610mm)
2 FT (610mm)
4 FT (1.22m)
4 FT (1.22m)
6 FT (1.86m)
6 FT (1.86m)
8 FT (2.48m)
8 FT (2.48m)
16 FT (4.8m)
16 FT (4.8m)
V + V
+ H + H
MAX. = 40 FT (12.2m)
1
1
H
(MAX.)
1
(MAX.)
1
V

Advertisement