AMG Systems AMG5414R Instruction Manual

Receive unit with one bi-directional data channel and one bi-directional alarm for a multimode fibre link

Advertisement

Quick Links

Receive Unit with one Bi-directional Data Channel and one
Bi-directional Alarm for a Multimode Fibre Link
The AMG5414R is rackmount receive unit designed to transmit and receive 1 data signal plus 1 Bi-
directional alarm over one Multimode optical fibre.
The AMG5414R is designed to plug into an AMG2009 or AMG2015 subrack, which in turn fits into a
19" rack system.
The AMG5414R is designed to operate with an AMG5413 / AMG5413R single channel or AMG5423 /
AMG5423R dual channel transmit unit in a point to point configuration. The R suffix in the partno.
indicates a rackmount configuration.
AMG Systems Ltd. reserves the right to make changes to this
document without notice. The information herein is believed to
be accurate. No responsibility is assumed by AMG for its use.
AMG5414R
Instruction Manual
Page 1 of 8
AMG5414R Instruction Sheet D17398-
00.doc

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AMG5414R and is the answer not in the manual?

Questions and answers

Summary of Contents for AMG Systems AMG5414R

  • Page 1 The AMG5414R is rackmount receive unit designed to transmit and receive 1 data signal plus 1 Bi- directional alarm over one Multimode optical fibre. The AMG5414R is designed to plug into an AMG2009 or AMG2015 subrack, which in turn fits into a 19" rack system.
  • Page 2 Dimensions ..................Error! Bookmark not defined. Mounting Details ................. Error! Bookmark not defined. Safety Maintenance and Repair AMG Systems Ltd. reserves the right to make changes to this Page 2 of 8 AMG5414R Instruction Sheet D17398- document without notice. The information herein is believed to 00.doc...
  • Page 3 Optical Connection The AMG5414R connections are illustrated in the following example which shows an AMG5413R transmit unit together with an AMG5414R receive unit configured as a single channel point to point system. AMG Systems Ltd. reserves the right to make changes to this...
  • Page 4 Alarm Input .......... Contact Closure pull-up is 330R to +3V3 Alarm Output ........Solid-state Relay, maximum 150mA at 125Vac/dc, Ron < 6.5Ω AMG Systems Ltd. reserves the right to make changes to this Page 4 of 8 AMG5414R Instruction Sheet D17398- document without notice.
  • Page 5 ALARM OUT ........Green Alarm ON / Contacts closed. Alarm OFF / Contacts open. AMG Systems Ltd. reserves the right to make changes to this Page 5 of 8 AMG5414R Instruction Sheet D17398- document without notice. The information herein is believed to 00.doc...
  • Page 6 The system detects a tri-state input condition on the data channel bus when in RS-485 or RS-422 mode. AMG Systems Ltd. reserves the right to make changes to this Page 6 of 8 AMG5414R Instruction Sheet D17398- document without notice.
  • Page 7 Alarm OUT ALARM IN + ALARM OUT - ALARM OUT + AMG Systems Ltd. reserves the right to make changes to this Page 7 of 8 AMG5414R Instruction Sheet D17398- document without notice. The information herein is believed to 00.doc...
  • Page 8 There are no user serviceable parts within AMG products. See unit data sheet for full specification. In case of problem or failure, please call your local support centre or contact: AMG Systems Ltd. at 3 The Omega Centre, Stratton Business Park, Biggleswade, Beds., SG18 8QB, UK.

Table of Contents