Auto Restart Control; Indication Panel; Patrol Operation - Panasonic CS-S18HKQ Service Manual

Indoor unit outdoor unit
Table of Contents

Advertisement

12.8. Auto Restart Control

1. When the power supply is cut off during the operation of air conditioner, the compressor will re-operate within three to four
minutes there are 10 patterns between 2 minutes 58 seconds and 3 minutes 52 seconds to be selected randomly. After power
supply resumes.
2. This type of control is not applicable during ON/OFF Timer setting.

12.9. Indication Panel

LED
POWER
Color
Green
Light ON
Operation ON
Light OFF
Operation OFF Timer Setting OFF Quiet Mode OFF
Note:
• If POWER LED blinks, the possible operation of the unit is operation mode judgment, or ON timer sampling.
• If Timer LED blinks, there is an abnormal operation occurs.
• If e-ion LED blinks, there is an abnormal e-ion operation occurs.
• If PATROL LED blinks, there is gas sensor error detection.

12.10. Patrol Operation

• To monitor air dirtiness level by using Patrol sensor and to maintain air freshness by activates e-ion operation.
• Patrol operation starts condition
- When the unit operation is started with "OFF/ON" button.
- When the unit stops, "Patrol" button is pressed, Patrol individual operation will start.
- During cooling only operation, "Patrol" button is pressed.
TIMER
QUIET
Orange
Orange
Timer Setting ON Quiet Mode ON
POWERFUL
e-ion
Orange
Blue
Powerful Mode
e-ion ON
ON
Powerful Mode
e-ion OFF
OFF
34
PATROL
Blue
Orange
Red
Air Clean Moderate
Dirty
PATROL OFF

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cs-s24hkqCu-s18hkqCu-s24hkq