12.8. Auto Restart Control
1. When the power supply is cut off during the operation of air conditioner, the compressor will re-operate within three to four
minutes there are 10 patterns between 2 minutes 58 seconds and 3 minutes 52 seconds to be selected randomly. After power
supply resumes.
2. This type of control is not applicable during ON/OFF Timer setting.
12.9. Indication Panel
LED
POWER
Color
Green
Light ON
Operation ON
Light OFF
Operation OFF Timer Setting OFF Quiet Mode OFF
Note:
• If POWER LED blinks, the possible operation of the unit is operation mode judgment, or ON timer sampling.
• If Timer LED blinks, there is an abnormal operation occurs.
• If e-ion LED blinks, there is an abnormal e-ion operation occurs.
• If PATROL LED blinks, there is gas sensor error detection.
12.10. Patrol Operation
• To monitor air dirtiness level by using Patrol sensor and to maintain air freshness by activates e-ion operation.
• Patrol operation starts condition
- When the unit operation is started with "OFF/ON" button.
- When the unit stops, "Patrol" button is pressed, Patrol individual operation will start.
- During cooling only operation, "Patrol" button is pressed.
TIMER
QUIET
Orange
Orange
Timer Setting ON Quiet Mode ON
POWERFUL
e-ion
Orange
Blue
Powerful Mode
e-ion ON
ON
Powerful Mode
e-ion OFF
OFF
34
PATROL
Blue
Orange
Red
Air Clean Moderate
Dirty
PATROL OFF