Wiring Diagram - Viessmann VITOFLAME 200 Service Instructions Manual

Gas pressure jet burner (type vga) for vitola and vitorond 200 rated output 15 to 63 kw
Hide thumbs Also See for VITOFLAME 200:
Table of Contents

Advertisement

Additional information

Wiring diagram

Control unit
components
On−site
supply
27/28
Gas pressure
valve
Burner motor
Air pressure
valve
Ign.
transformer
Gas valves
Flame monitor
Function sequence during start−up
Ext. burner
Gas pressure
Air pressure
fault
valve
valve
Control program LMG 21.330
Control program LMG 21.350
TW − Waiting time
approx.
8s
TW − Waiting time
T10 − Default time for
T10 − Default time for
air pressure signal
min.
5s
air pressure signal
T1 − Pre−flush time
min. 30s
T1 − Pre−flush time
TSA − Safety time start−up
max.
3s
TSA − Safety time start−up
T3 − Pre−ignition time
approx.
2s
T3 − Pre−ignition time
Burner
Gas
Op. lamp or
motor
valve
hours run counter
ext. (control unit)
Legend
fA
Burner plug on the control unit
F 1.1
Fuse in plug−in module
TR/STB Safety equipment inside the
control unit
K..
Burner relay contact
approx.
8s
1 qW Plug−in terminals on the gas
burner control unit
min.
5s
A
Start command
min. 30s
B − B'
Interval for the flame to be
max.
5s
approx.
2s
established
C
Burner operating position
achieved
C − D
Burner operation
D
Controlled switch−off
Colour coding conforming to DIN/IEC 757
Ign.
Flame
BK
black
transformer
monitor
BN
brown
BU
blue
GNYE green/yellow
RD
red
1)
Connection of assembly modules and
accessories via system plug−in connector fA
(e.g. KNL, extension lead, etc.)
2)
Connection of external safety equipment via
system plug−in connector aBÖ
3)
Connection of external control off−switch via
system plug−in connector aBÖ
4)
Connection for external burner ON
Please note:
This wiring diagram only applies in
conjunction with Viessmann products.