3onedata IMC102B-F User Manual page 2

Industrial ethernet media converter

Advertisement

【Dimension】
Unit (mm)
【DIP Switch】
Top panel provides 4-pin DIP switch to configure the device
(ON to enable effective). 1 is used to configure frame flow
control of RJ45 port and the optic fiber port support back
press flow control. 2 is force RJ45 to 10M. 3 and 4 is
reserved.
【Communication connector】
10/100Base-T(X) Ethernet port
The pinout define of RJ45 port display as below, connect by
UTP or STP. The connection distance is no more than 100m.
100Mbps is used 120Ω of UTP 5, 10Mbps is used 120Ω of
UTP 3, 4, 5.
RJ 45 port support automatic MDI/MDI-X operation. Can
connect the PC, Server, Converter and HUB .Pin 1,2,3,6
Corresponding connections in MDI. 1→3, 2→6, 3→1, 6→2
are used as cross wiring in the MDI-X port of Converter and
HUB. 10Base-T/100Base-TX are used in MDI/MDI-X, the
define of Pin in the table as below.
NO.
MDI signal
1
TX+
1
8
2
TX-
3
RX+
6
RX-
4, 5, 7, 8
Note: , "TX±"transmit data±, "RX±"receive data±, "—"not use.
10/100Base-T(X) MDI (straight-through cable)
10/100Base-T(X) MDI-X (Cross over cable)
MDI/MDI-X auto connection makes converter easy to use for
customers without considering the type of network cable.
100Base-FX SC/ST/FC port
100Base-FX port support full-duplex SC/ST/FC Multi mode
or Single mode. The fiber port TX (transmit) connect remote
RX (receive).
- 2 -
MDI-X signal
Suppose: If you make your own cable, we suggest labeling
the two sides of the same line with the same letter (A-to-A
RX+
and B-to-B, shown as above, or A1-to-A2 and B1-to-B2).
RX-
【LED Indicator】
TX+
LED indictor light on the front panel of product, the function
TX-
of each LED is described in the table as below.
LED
PWR
Link/ACT
(1~3)
【Installation】
Before installation, ensure that the working environment
meet the installation requirement, including the power needs
and abundant space. Whether it is close to the connection
equipment and other equipments are prepared or not.
1. Avoid in the sunshine, keep away from the heat
fountainhead or the area where in intense EMI.
2. Check
the
requirements.
3. Check whether the cables be seemly or not (less than
100m) according to reasonable scheme.
4. Power: support 100~240VAC power supply;
5. Environment: working temperature: -40~75℃
DIN Rail Installation
In order to use in industrial environments expediently, the
product adopt 35mm DIN-Rail installation, the installation
steps as below:
LED system statue
State
Description
The device is powered on and is
ON
working properly.
OFF
The device is powered off.
The Ethernet port is connected
ON
properly.
The Ethernet port is connected
Blinking
and data is being transmitted.
The Ethernet port is not
OFF
connected properly.
cables
and
plugs
that
installation
Storage Temperature: -40~85℃
Relative humidity 5%~95%