A17 Transformer Test

To Test Transformer:
1. Leave transformer connector J4 plugged into the circuit board.
2. Set your Voltmeter to the 500 VAC range.
3. Place Voltmeter probes directly into backside (wire side) of J4 connector and test as follows:
North American 60 Hz
J-315/J-325 (120 VAC or 240 VAC Powered*)
Connector J4
Black to White
Yellow to Yellow
*Special instructions for all 120 VAC/240 VAC convertible power models.
120 VAC Power Configuration: Convertible models include a factory installed 10 foot GFCI cord
rated at 15A/120 VAC. To use cord the hot tub must be installed within 10 feet of a dedicated,
grounded type electrical outlet. Do not use an extension cord of any type! If the hot tub is more than
10 feet from an outlet, it must be hard wired to a single pole 15 amp GFCI breaker. Refer to pages
43-46 for specific circuit board configurations.
240 VAC Power Configuration: Convertible models can be hard wired for 4-wire 120 VAC/240
VAC power. This configuration powers the heater with 240 VAC while powering both pumps and
ozone with 120 VAC. An external 30 or 40 amp dual pole GFCI breaker is required. Refer to pages
43-46 for specific circuit board configurations.
North American 60 Hz
J-335, J-345, J-355, J-365, J375, J385 (240 VAC Powered)
Connector J4
Black to Red
Yellow to Yellow
All Export 50 Hz Models
230 VAC Powered
Connector J4
Black to Black
Yellow to Yellow
Voltage
120 VAC*
12-14 VAC*
Voltage
240 VAC
12-14 VAC
Voltage
230 VAC
12-14 VAC
120 VAC/240 VAC
Convertible Models*
(Wire End View)
BK
Y
W
Y
240 VAC Models
(Wire End View)
Export 50 Hz Models
(Wire Side View)
Blk
Y
Blk
Y