Windows Vista; Windows 7; Correcting An Ip Address - IBM S824L Installing

Table of Contents

Advertisement

Windows Vista

To set the IP address within Windows Vista, complete the following steps:
1. Click Start > Control Panel.
2. Ensure Classic View is selected.
3. Click Network and Sharing Center.
4. Click View status in the Public network area.
5. Click Properties.
6. If the Security window is shown, click Continue.
7. Highlight Internet Protocol Version 4 and click Properties.
8. Select Use the following IP address.
9. Complete the IP address, Subnet mask, and Default gateway fields by using the values that you
recorded in the "Accessing the ASMI by using a web browser" on page 24 topic.
10. Click OK > Close > Close.

Windows 7

To set the IP address within Windows 7, complete the following steps:
1. Click Start > Control Panel > Network and Internet > Network and Sharing Center.
2. Click Change adapter settings to choose your network adapter.
3. Right-click the adapter and choose Properties to open up the properties window.
4. Select Internet Protocol Version 4(TCP/IPv4), and then click Properties.
Attention: Record the current settings before you make any changes. Use this information to restore
these settings if you disconnect the PC or notebook after you set up the ASMI web interface.
5. Select Use the Following IP Address.
6. Complete the IP address, Subnet mask, and Default gateway fields by using the values that you
recorded in the "Accessing the ASMI by using a web browser" on page 24 topic.
7. In the Local Area Connection Properties window, click OK. It is not necessary to restart your PC.

Correcting an IP address

If you attach an Ethernet cable to the service processor before the system reaches power off standby, the
IP address shown in the service processor network configuration table might not be valid.
If a cable is attached and not connected to anything, nothing happens. The address could potentially
change if an Ethernet cable that is attached to a network is connected to that port and if the system is
turned on. If you are unable to access the Advanced System Management Interface (ASMI by using a
network connection, complete one of the following tasks:
v Using a serial cable that is equipped with a null modem, connect the ASCII terminal to the serial port
on the rear of the server.
v Determine the current IP address. For details, see Function 30: Service processor IP address and port
location(http://publib.boulder.ibm.com/infocenter/systems/scope/hw/topic/p8hb5/func30.htm).
v Move the reset toggle switches on the service processor from their current position to the opposite
position. To perform this task, you must remove and replace the service processor. For details, contact
your next level of support.
26
Power Systems: Installing the IBM Power System S824L (8247-42L)