IBM S824L Installing page 19

Table of Contents

Advertisement

Figure 1. Removing the filler panels
4. Face the front of the rack and work from the left side to complete the following steps:
Remember: If you received a mounting template, you can use the template to mark the locations
instead of using the manual method.
a. Make a note of both the lowest and highest EIA units to be used for the drawer.
b. Use tape, a marker, or a pencil to mark the top mounting hole (A) of the third EIA unit. Insert a
nut clip at this location.
c. Mark the top mounting hole on the lowest EIA unit.
Note: Mark the rack so that these marks can also be seen from the rear of the rack.
d. Count up two holes and place another mark (B) beside that mounting hole. You now have two (B)
marks on the rack, with one mounting hole between the marks.