ITC T-2S60 Operation Manual

2-channel amplifier

Advertisement

Quick Links

T-2S60
T-2S120
T-2S240
T-2S350
T-2S500
2-CHANNEL AMPLIFIER
Please follow the instructions in this manual to obtain the optimum results from this unit.
We also recommend that you keep this manual handy for future reference.
PUBLIC ADDRESS SYSTEM
T-2S60
2-CHANNEL AMPLIFIER
ON
OFF
T-2S120
2-CHANNEL AMPLIFIER
ON
OFF
T-2S240
2-CHANNEL AMPLIFIER
ON
OFF
T-2S350
2-CHANNEL AMPLIFIER
ON
OFF
T-2S500
2-CHANNEL AMPLIFIER
ON
OFF
SIGNAL
CLIP PROT TEMP
SIGNAL
CLIP PROT TEMP
CH1
CH2
CH 1
CH 2
POWER
VOLUME
VOLUME
5
5
4
6
4
6
3
7
3
7
8
8
2
2
1
9
1
9
0
10
0
10
SIGNAL
CLIP PROT TEMP
SIGNAL
CLIP PROT TEMP
CH1
CH2
CH 1
CH 2
POWER
VOLUME
VOLUME
5
5
4
6
4
6
3
7
3
7
2
8
2
8
1
9
1
9
0
10
0
10
SIGNAL CLIP PROT TEMP
SIGNAL CLIP PROT TEMP
CH1
CH2
POWER
CH 1
CH 2
VOLUME
VOLUME
5
5
4
6
4
6
3
7
3
7
2
8
2
8
1
9
1
9
0
10
0
10
SIGNAL CLIP PROT TEMP
SIGNAL CLIP PROT TEMP
CH1
CH2
POWER
CH 1
CH 2
VOLUME
VOLUME
5
5
4
6
4
6
3
7
3
7
2
8
2
8
1
9
1
9
0
10
0
10
SIGNAL CLIP PROT TEMP
SIGNAL CLIP PROT TEMP
CH1
CH2
POWER
CH 1
CH 2
VOLUME
VOLUME
5
5
4
6
4
6
3
7
3
7
2
8
2
8
1
9
1
9
0
10
0
10

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the T-2S60 and is the answer not in the manual?

Questions and answers

Summary of Contents for ITC T-2S60

  • Page 1 PUBLIC ADDRESS SYSTEM SIGNAL CLIP PROT TEMP SIGNAL CLIP PROT TEMP T-2S60 2-CHANNEL AMPLIFIER T-2S60 CH 1 CH 2 POWER VOLUME VOLUME SIGNAL CLIP PROT TEMP SIGNAL CLIP PROT TEMP T-2S120 2-CHANNEL AMPLIFIER CH 1 CH 2 POWER VOLUME VOLUME...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS 1. SAFETY PRECAUTIONS ..................3 2. GENERAL DESCRIPTION ..................5 3. FEATURES ......................5 4. NOMENCLATURE AND FUNCTIONS 4.1 Front Panel(2U) ...................... 6 4.2 Rear Panel(2U).......................7 4.3 Front Panel(3U)....................... 8 4.4 Rear Panel(3U).......................9 4.5 Rear Panel(3U)......................10 5. CONNECTIONS ......................
  • Page 3: Safety Precautions

    1. SAFETY PRECAUTIONS Be sure to read the instructions in this section carefully before use. Make sure to observe the instructions in this manual as the conventions of safety symbols and messages regarded as very important precautions are included. We also recommend you keep this instruction manual handy for future reference. Safety Symbol and Message Conventions Safety symbols and messages described below are used in this manual to prevent bodily injury and property damage which could result from mishandling.
  • Page 4 When removing the power cord, be sure to hold its plug to pull. Contact your ITC dealer as to the cleaning. If dust is allowed to accumulate in the unit over a long Do not block the ventilation slots in the unit's cover.
  • Page 5: General Description

    With two separate power amplififers in a single chassis and power ratings from 60 to 500 watts RMS, these sleek, attractive units provide a compact solution for ITC system amplification and distribution.Both balanced and unbalanced line inputs make it selectable for installer, balanced line output feeds to another power amplifier as well as secures the signal transmission is less noise and longer distance.
  • Page 6: Nomenclature And Functions

    4. NOMENCLATURE AND FUNCTIONS 4.1 FRONT PANEL(2U) SIGNAL CLIP PROT TEMP SIGNAL CLIP PROT TEMP CH 1 CH 2 POWER VOLUME VOLUME 1. POWER SWITCH On top of the opening Power Press the end, power shut down 2. CH1\CH2 VOLUME volume control 3.
  • Page 7: Rear Panel(2U)

    NOMENCLATURE AND FUNCTIONS 4.2 REAR PANEL(2U) CH 2 INPUTS CH 2 LINK INPUTS LINK XLR BAL 1-GND 2-HOT+ 3-COLD- OUTPUTS 2 OUTPUTS 1 LIFT CH 1 INPUTS CH 1 LINK ¦¸ ¦¸ ¦¸ ¦¸ 8. ~220-240V 50/60Hz POWER INPUT 9. OUTPUTS2 Connectors for 4 ohms or 70V and 100V speaker 10.
  • Page 8: Front Panel(3U)

    NOMENCLATURE AND FUNCTIONS 4.3 FRONT PANEL(3U) SIGNAL CLIP PROT TEMP SIGNAL CLIP PROT TEMP POWER CH 1 CH 2 VOLUME VOLUME 1. POWER SWITCH On top of the opening Power Press the end, power shut down 2. CH1\CH2 VOLUME Channel volume control 3.
  • Page 9: Rear Panel(3U)

    NOMENCLATURE AND FUNCTIONS 4.4 REAR PANEL(3U) CH 2 INPUTS CH 2 LINK INPUTS LINK XLR BAL LIFT 1-GND 2-HOT+ 3-COLD- OUTPUTS 2 OUTPUTS 1 CH 1 INPUTS CH 1 LINK ¦¸ ¦¸ ¦¸ ¦¸ 8. ~220-240V 50/60Hz POWER INPUT 9. OUTPUTS2 Connectors for 4 ohms or 70V and 100V speaker 10.
  • Page 10: Rear Panel(3U)

    NOMENCLATURE AND FUNCTIONS 4.5 REAR PANEL(3U) CH 2 INPUTS CH 2 LINK INPUTS LINK XLR BAL LIFT 1-GND 2-HOT+ 3-COLD- OUTPUTS 2 OUTPUTS 1 CH 1 INPUTS CH 1 LINK ¦¸ ¦¸ ¦¸ ¦¸ 8. ~220-240V 50/60Hz POWER INPUT 9. OUTPUTS2 Connectors for 4 ohms or 70V and 100V speaker 10.
  • Page 11: Connections

    5. CONNECTIONS SPEAKER CONNECTIONS 100V 100V (T-2S60) (T-2S120) (T-2S350) (T-2S240) (T-2S500) 70V LINE 100V (T-2S60) (T-2S120) (T-2S350) (T-2S240) (T-2S500) 100V LINE 70V/...
  • Page 12: Machine Operation

    6. MACHINE OPERATION MIC INPUT CHANNEL 1~3 This is a special connector which will accept 3-conductor XLR. These inputs are suitable to receive signal from microphones level devices. MIC JACK (XLR JACK) LINE JACK (TRS PHONE JACK) Pin 1:GROUND Sleeve:GROUND Pin 2:HOT(+) Tip:HOT(+) Pin 3:COLD(-)
  • Page 13: Applications

    7. APPLICATIONS REAR PANEL CONNECTIONS...
  • Page 14 APPLICATIONS REAR PANEL CONNECTIONS...
  • Page 15: Block Diagram

    8. BLOCK DIAGRAM...
  • Page 16: Specifications

    9. SPECIFICATIONS MODEL T-2S60 T-2S120 T-2S240 RATED POWER OUTPUT 2X60W 2X120W 2X240W SPEAKER OUTPUTS 4 ,70V/100V INPUT SENSITIVITY 775mV/0dB FREQUENCY RESPONSE 50Hz~15KHz 3dB S/N RATIO >90dB T.H.D <1% Compulsive wind cooling RADIATOR METHOD Power, Signal, Protection and Overheat INDICATORS Power,Overheat, Overload and short-circuit...
  • Page 17 SPECIFICATIONS MODEL T-2S350 T-2S500 RATED POWER OUTPUT 2X350W 2X500W SPEAKER OUTPUTS 4 ,70V/100V INPUT SENSITIVITY 775mV/0dB FREQUENCY RESPONSE 50Hz~15KHz 3dB S/N RATIO >90dB T.H.D <1% Compulsive wind cooling RADIATOR METHOD Power, Signal, Protection and Overheat INDICATORS Power,Overheat, Overload and short-circuit PROTECTION POWER REQUIREMENTS ~220-240V 50/60Hz...
  • Page 18: Dimensional Diagram

    10. DIMENSIONAL DIAGRAM UNIT :mm SIGNAL CLIP PROT TEMP SIGNAL CLIP PROT TEMP CH 1 CH 2 POWER VOLUME VOLUME CH 2 INPUTS CH 2 LINK INPUTS LINK XLR BAL 1-GND 2-HOT+ 3-COLD- OUTPUTS 2 OUTPUTS 1 LIFT CH 1 INPUTS CH 1 LINK ¦¸...
  • Page 19 DIMENSIONAL DIAGRAM UNIT:mm SIGNAL CLIP PROT TEMP SIGNAL CLIP PROT TEMP POWER CH 1 CH 2 VOLUME VOLUME CH 2 INPUTS CH 2 LINK INPUTS LINK XLR BAL LIFT 1-GND 2-HOT+ 3-COLD- OUTPUTS 2 OUTPUTS 1 CH 1 INPUTS CH 1 LINK ¦¸...
  • Page 20 PUBLIC ADDRESS SYSTEM PUBLIC ADDRESS SYSTEM VersionV0.4...

This manual is also suitable for:

T-2s120T-2s240T-2s350T-2s500

Table of Contents