PAW HeatBloC K36E Installation And Operation Instructions Manual page 14

Boiler charging set
Table of Contents

Advertisement

14
Assembly with wall bracket
-
Fix the wall bracket to the wall with the enclosed
screws and washers.
-
Screw the HeatBloC with the coupling piece for
overhead installation (G-3) to the wall bracket.
Only for the assembly under a modular distribution
manifold
-
Mount the distribution manifold on the PAW wall
bracket. You can mount the heating circuit K36E
directly on the connections of the manifold. Remove
the plugs in the pipe connections of the modular
distribution manifold if necessary.
Assembly on a wall bracket
-
Fix the wall bracket to the wall with the enclosed
screws and washers.
-
Insert the clip springs in the lower ball valves.
-
First insert the back part of the insulation and then
the valves and fittings on the wall bracket.
Piping
1. Connect the HeatBloC to the installation by using the
pipes.
The hydraulic schemes for both assembly versions
can be found on pages 6 and 7.
The installation to the pipes must be carried out
without any tension.
2. Connect the pump.
3. Carry out a pressure test and check all thread
connections.
4. After commissioning, mount first the front insulating
elements and then the ball valve handles with
thermometer.
993x03x3x-mub-en – V01
4 Assembly and installation [specialist]
2017/01