10 Configuration

10.1 To set a different address

CVXM20A + FVXM25~50A
Split system air conditioners
4P625991-1C – 2021.09
In case 2 indoor units are installed in 1 room, different addresses for 2 user
interfaces can be set.
1 Remove the cover and the batteries from the user interface.
2 Cut the address jumper J4.
Address jumper J4
Factory setting
After cutting with nippers
a Address jumper J4
NOTICE
Be careful NOT to damage any of the surrounding parts when cutting the address
jumper.
3 Turn the power supply on.
4 Press the middle of
5 Press
, select and press
Result: The Daikin eye will start to blink.
6 Press the indoor unit ON/OFF switch while the Daikin eye is blinking.
INFORMATION
If the setting could NOT be completed while the Daikin eye was blinking, repeat the
setting process from the beginning.
Address
1
2
a
and
simultaneously.
.
10