Hydraulic Tank Installation - Efco Swaploader SL-330 Parts And Operation Manual

Table of Contents

Advertisement

1.
Select a location to mount the hydraulic tank. Reference Figure G or Drawing No.
90H57 for the suggested location of the hydraulic tank to the rear of the control valve
assembly on the left-hand side of the truck. The hydraulic hoses have been sized for the
tank to be mounted in this general area. The tank can be located on the right-hand side or
behind the cab, if necessary, which means longer hoses may be required.
2.
Drill four (4) holes for 1/2-inch diameter bolts (provided) in the mount angle of the
hydraulic tank (two per angle) and the frame rails of the truck chassis. Mount the
hydraulic tank and install the hydraulic filter. Install the hydraulic return hose and the
hose barb fitting between the filter and the control valve assembly as shown on Drawing
No. 91H03. The hose length can be shortened if necessary. Secure the hose to the barb
fittings with the hose clamps provided.
SL-330.INS
09/2009

HYDRAULIC TANK INSTALLATION

Figure G
2-15