DESCRIPTION
Connect/Disconnect
VLAN Settings
Unit Name
SIP Server
Peer to Peer Settings
Outbound Proxy
Authentication ID
Register Fails
Phone Number Database
Event Log
Entry Code Database
Keyless / Card Logging
Security code (factory set to 845464)
Access Code (1 - 6 digits, blank = disabled, factory set to 123456)
Weigand Direction
Select Time Zone
Daylight Savings
Internal / External Relays (factory set to Internal)
Relay Mode (Door Strike, Outbound Call, In / Outbound Call, Doorbell, Alarm, Ring, Ring Flash, factory set to Door Strike)
Relay Act (Activation) Command (1 or 2 digits, factory set to ,,) NOTE: Relay Mode must be set to Door Strike
Relay Act (Activation) Time (0.5 - 99 seconds, factory set to 5 seconds)
Relay Activation Delay (Disabled or 0.5 - 99 seconds, factory set to Disabled)
Relay Latch Commands (Enabled or Disabled, factory set to Enabled) NOTE: Relay Mode must be set to Door Strike
In-Band Audio Call Progress (Enabled, Disabled, factory set to Enabled)
In-Band Audio Detect Sensitivity (1 - 9, 1 = minimum, 9 = maximum, factory set to 5, power cycle unit after setting)
Handset Default Volume
Phone Mode (Auto Dialer or Manual Dial Phone, factory Set to Auto Dialer)
Call Length Time Out (disabled or 1 - 9 minutes, factory set to 3 minutes)
Inbound Call Mode (Disabled, Auto Answer, Auto Answer-Secure, Ring Low, Ring High, Silent Monitor, Silent Monitor Secure, Factory
set to Auto Answer)
Ring Cadence (factorty set to Normal Ring, 2 seconds on 4 seconds off)
Dial Next Number on RNA (Ring No Answer) (disabled, 1 - 9 = number of rings, factory set to 7)
Dial Next Number on Busy (disabled or enabled, factory set to enabled)
In Call Dialing Format (Inband DTMF or RFC2833, factory set to RFC2833)
Off Hook Dialing Delay
Off Hook Auto Dial
Mute Current / Next Alarm
Permanent Alarm Mute
IP Firmware
Unit Firmware
Import/Export
Clear Unit Settings
Clear IP Settings
Diagnostics (used to check mic, speaker, relays and proximity card reader operation)
REX Input
Programming Features Index
10
Section
Page
B
7
D
9
1
11
2
11
3
11
4
11
5
11
6
11
7
12
8
13
9
13
10
14
11
14
12
14
13
14
14
14
15
14
16
15
17
15
18
16
19
16
20
16
21
16
22
16
23
16
24
16
25
16
26
17
27
17
28
17
29
17
30
17
31
18
32
18
33
18
34
18
35
19
36
19
37
19
38
19
39
19
40
19
41
19
42
19

Advertisement

Table of Contents
loading

This manual is also suitable for:

K-1900-8-ip seriesK-1900812lipewpK-1900-8-ipK-1900-8-ip-ewp

Table of Contents