Advertisement

Quick Links

Installation & Operation Manual
We thank you very much for using the Yoshitake Products. In order to put in
use our product correctly and safely, please make sure to read this manual
thoroughly prior to the installation. Also we kindly request you to keep this
manual with care at your hand.
Warning
Caution
1. Overview ············································································ 1
2. Specifications ······································································ 1
3. Dimensions and Weights ···················································· 1
4. Operation ············································································· 2
5.1. Stainer of diameter ····················································· 3
5.2. Selection of pipe diameter ············································ 3
5.3. Pressure loss diagram ··················································· 4
6.1. Example of piping ··························································· 5
8.1. Troubleshooting ····························································· 7
8.3. Disassembly Procedure ················································· 7
8.4. Assembly Procedure ····················································· 8
8.5 Assembly ········································································· 8
8.6 Exploded drawing ···························································· 8
TYPE SY-20
STRAINER
The following safety symbols are used in this manual.
Indicates that mishandling this product might cause fatal or
serious bodily injury.
Indicates that mishandling this product might cause bodily
injury or material damage.

Table of Contents

■EPDT-147b■

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SY-20-10 and is the answer not in the manual?

Questions and answers

Summary of Contents for Yoshitake SY-20-10

  • Page 1: Table Of Contents

    STRAINER Installation & Operation Manual We thank you very much for using the Yoshitake Products. In order to put in use our product correctly and safely, please make sure to read this manual thoroughly prior to the installation. Also we kindly request you to keep this manual with care at your hand.
  • Page 2: Overview

    1.Overview Used in wide range of purpose as dust removing from water and oil. Mainly used for cooling water and water for industrial use. 2.Specifications Type SY-20-10 SY-20-20 Connection JIS 10K RF JIS 20K RF Nominal Size 15A~150A Application Steam・Air・Cold and hot water・Oil・Other non-dangerous fluids Maximum Pressure 1.0MPa 2.0MPa...
  • Page 3: Operation

    SY-20-10 (mm) Screen Plug Weight Size L H d 1 ds ls (kg) 15A 160 104 65.5 15 R 3/8 20A 160 113 71.5 20 R 3/8 25A 180 122 76.0 25 R 3/8 32A 240 154 105.0 40 R 1/2 40A 240 154 105.0 40 R 1/2...
  • Page 4: Pressure Loss

    5.Pressure loss To use the strainer most effectively and to fulfill the required criteria thoroughly, please take the following points into consideration. Selection of strainer diameter The same one as the piping size is selected(piping size=strainer size) if a small size is used,pressure drop glows and pressure prescribed at the entrance of the equipment might not be able to be maintained.
  • Page 5: Pressure Loss Diagram

    Pressure loss diagram (Fluid Water) Screen:Perforated plateφ 6.0-1.80holes/cm Element 80mesh ■EPDT-147b■...
  • Page 6: Installation

    6.Installation Example of piping Figure-1 Figure-3 Figure-2 Precautions during installation and inspection Warning (1) Because of heavy weight, hold the valve with lifting equipment while piping. Refer to “3. Dimensions and weights” table for the valve weight. ※Failure to do so may result in injury due to dropping the valve. Caution (1) When installing, confirm if the direction of fluid flow matches with inlet and outlet port of the product respectively.
  • Page 7: Operating Procedure

    (mm) Size H 100A 125A 150A Figure-4 7.Operating Procedure 7.1 Precautions during operation and inspection Warning (1)Prior to letting the fluid run in the system, make sure that there is no danger when the fluid flows out of pipe end. ※In case the fluid of high temperature flows out of pipe end, there will be a danger of personnel being scalded.
  • Page 8: Maintenance Procedure

    8.Maintenance Procedure Troubleshooting Countermeasure and Trouble condition Cause of trouble remedy No fluid flows. 1.Screen③ is clogged up. 1.Disassemble and clean the screen③. 2.Stop valves at inlet and/or 2.Open stops valves. outlet side are shut. Pressure loss is 1.Screen③ is clogged up. 1.Disassemble and excessive.
  • Page 9: Assembly Procedure

    Assembly Procedure Caution (1) When re-assembling, fix the relative parts properly. ※Parts may be deformed or damaged. (2) Tighten the bolts evenly on each bolt in turn of diagonal position. ※The fluid may leak from strainer. If the fluid is of high temperature, the leakage may cause being scalded.
  • Page 10 Fire, flood, earthquake, thunder and other natural disasters. Consumable parts such as O-ring, gasket, diaphragm and etc. Yoshitake is not liable for any damage or loss caused by malfunction or defect of the product. INTERNATIONAL DEPT. 955-5, Miyamae, Irukadeshinden, Komaki, Aichi, 485-0084, Japan...