PERMANENT WIRING INSTALLATION

WARNING:
MAKE SURE POWER SUPPLY CORD IS DISCONNECTED TO AVOID ANY ELECTRIC SHOCK
BEFORE SERVICING. ELECTRIC SHOCK MAY CAUSE SERIOUS INJURY.
INSTALLATION SHOULD BE CONDUCTED BY A LICENSED ELECTRICIAN.
Step 1.
Disconnect power supply cord
from power source.
Remove two (2) screws on the
front panel of the heater.
Step 2.
Disconnect ground wire (green
wire) from the power supply
cord bracket.
Step 3.
Disconnect two power supply
wires from right side of the
terminal.
NOTE:
Emergency power supply and use of 12V DC batteries with an inverter. Consult your dealer before
attempting to use a battery/inverter system to provide power for your Laser heater. These units require
true sine wave power for proper long-term operation. Some types of modified or block sine wave
inverters will cause damage to the electrical components of the heater. Several inverter
manufacturers offer true sine wave inverters which should operate the unit without any problems if
properly sized and configured. If you have any questions about appropriate power supply, consult your
authorized TOYOTOMI dealer.
Step 4.
Squeeze strain relief with the
adjustable pliers to remove
plastic bushing from the power
supply cord bracket.
Remove the power supply cord.
Step 5.
Insert the power supply cable
from the rear panel and connect
ground wire to the power supply
cord bracket and power wires to
the terminals.
Step 6.
Replace the front panel and
secure the two (2) screws.