PERMANENT WIRING INSTALLATION

WARNING:
MAKE SURE POWER SUPPLY CORD IS DISCONNECTED TO AVOID ANY ELECTRIC SHOCK
BEFORE SERVICING. ELECTRIC SHOCK MAY CAUSE SERIOUS INJURY.
INSTALLATION SHOULD BE CONDUCTED BY A LICENSED ELECTRICIAN.
Step 1.
Disconnect power supply cord
from power source.
Remove two (2) screws on the
front panel of the heater.
Step 2.
Disconnect ground wire (green
wire) from the power supply
cord bracket.
Step 3.
Disconnect two power
supply wires from right side of
the terminal.
NOTE:
Emergency power supply and use of 12V DC batteries with an inverter. Consult your dealer before
attempting to use a battery/inverter system to provide power for your Laser heater. These units require
true sine wave power for proper long-term operation. Some types of modified or block sine wave
inverters will cause damage to the electrical components of the heater. Several inverter
manufacturers offer true sine wave inverters which should operate the unit without any problems if
properly sized and configured. If you have any questions about appropriate power supply, consult your
authorized TOYOTOMI dealer.
Step 4.
Squeeze strain relief with the
adjustable pliers to remove
plastic
bushing
from
the
power supply cord bracket.
Remove the power supply
cord.
Step 5.
Insert the power supply cable
from
junction
box
and
connect ground wire to the
power supply cord bracket
and power wires to the
terminal.
Step 6.
Replace the front panel and
secure the two (2) screws.