6. Programming & Users management
The programming of the cards is stored in the memory of the device so the system is robust in the event of power supply
drops. In the absence of power supply the controller will not be able to activate the door opening, as it will not read the
cards.
The system supports up to 1000 user cards. Each of them is registered in the system as they are registered, with an
identifier (0, 1, 2, ... 999).
Important note:
It is not possible to know which identifier corresponds to each user card, so it is recommended that
a record is kept. Keeping the registry will allow deleting a user card (without physically having it). If
this is not the case, it will be necessary to delete and re-register all the cards.
6.1. Numbering of user cards
To keep a correct control of the identifier associated with each card, it is important to know that:
• The first card registered is the 000.
• The second will be 001, the third will be 002 and so on until the last (thousand) will be 999.
• If the third card is deleted, a hole (bubble) is created between 001 and 003.
• When registering a new card with the master cards, this bubble will be filled (the new card will be 002).
• With the remote control, you can force a card to have a specific identifier, leaving bubbles if desired.
• There cannot be two user cards with the same identifier.
It is recommended to register the identifier by relating it to the serial number of the card and to the user of the card. It is
not recommended to write down the identifier on the card itself. Should it be lost, the identifier to be removed from the
controller will not be known.
Identifier
0
1
...
999
6.2. Programming via keyboard (remote control)
The supplied remote control allows the programming of the controller. To do this, aim it to the IR sensor and press the
indicated commands.
6.2.1. Programming mode (via remote control)
In this mode it is possible to carry out the programming using the remote control by entering different commands.
To enter this mode, press:
Enter in the programming mode
Exit the programming mode
To change the master code:
Step 1
Enter in the programming mode
Insert the new master code
Step 2
Step 3
Exit the programming mode
If you change the master code, remember it. Otherwise it will be necessary to make a factory default reset.
It must have 6 digits.
Serial Number of the user card
0093119565
0093119566
...
0093117684
* <Master code> # (Default master code 123456)
*
4
Person / Department / Apartment
Mr. Juan Pérez
Ms. Marta López
...
Ms. Teresa Monte
* <Master code> #
0 <New master code> #
< New master code > #
*