3-4. NC CURVES
PLFY-M20VEM-(E/ET)
PLFY-M25VEM-(E/ET)
90
80
70
60
50
40
30
20
APPROXIMATE
THRESHOLD OF
HEARING FOR
CONTINUOUS
NOISE
10
63
125
250
500
BAND CENTER FREQUENCIES, Hz
PLFY-M63VEM-(E/ET)
90
80
70
60
50
40
30
20
APPROXIMATE
THRESHOLD OF
HEARING FOR
CONTINUOUS
NOISE
10
63
125
250
500
BAND CENTER FREQUENCIES, Hz
PLFY-M100VEM-(E/ET)
90
80
70
60
50
40
30
20
APPROXIMATE
THRESHOLD OF
HEARING FOR
CONTINUOUS
NOISE
10
63
125
250
500
BAND CENTER FREQUENCIES, Hz
OCH728A
NOTCH SPL(dB)
LINE
High
29
Medium1
27
Medium2
26
Low
24
NC-70
NC-60
NC-50
NC-40
NC-30
NC-20
1000
2000 4000
8000
NOTCH SPL(dB)
LINE
High
32
Medium1
30
Medium2
29
Low
28
NC-70
NC-60
NC-50
NC-40
NC-30
NC-20
1000
2000 4000
8000
NOTCH SPL(dB)
LINE
High
41
Medium1
39
Medium2
37
Low
34
NC-70
NC-60
NC-50
NC-40
NC-30
NC-20
1000
2000 4000
8000
PLFY-M32VEM-(E/ET)
PLFY-M40VEM-(E/ET)
PLFY-M50VEM-(E/ET)
90
80
70
60
50
40
30
20
APPROXIMATE
THRESHOLD OF
HEARING FOR
CONTINUOUS
NOISE
10
63
PLFY-M80VEM-(E/ET)
90
80
70
60
50
40
30
20
APPROXIMATE
THRESHOLD OF
HEARING FOR
CONTINUOUS
NOISE
10
63
PLFY-M125VEM-(E/ET)
90
80
70
60
50
40
30
20
APPROXIMATE
THRESHOLD OF
HEARING FOR
CONTINUOUS
NOISE
10
63
19
NOTCH SPL(dB)
High
31
Medium1
29
Medium2
27
Low
26
NC-70
NC-60
NC-50
NC-40
NC-30
NC-20
125
250
500
1000
2000 4000
8000
BAND CENTER FREQUENCIES, Hz
NOTCH SPL(dB)
High
37
Medium1
34
Medium2
31
Low
28
NC-70
NC-60
NC-50
NC-40
NC-30
NC-20
125
250
500
1000
2000 4000
8000
BAND CENTER FREQUENCIES, Hz
NOTCH SPL(dB)
High
45
Medium1
42
Medium2
39
Low
35
NC-70
NC-60
NC-50
NC-40
NC-30
NC-20
125
250
500
1000
2000 4000
8000
BAND CENTER FREQUENCIES, Hz
LINE
LINE
LINE