Prepare Your Installation Location; Cable Length Recommendations - Planar VM55MX-M2 User Manual

Table of Contents

Advertisement

8.4

Prepare Your Installation Location

Prepare the area where you will install the unit. If custom enclosures are part of the installation,
they must be fully designed to accommodate the installation of the displays, the installed units,
and ventilation and cooling requirements.
If your installation includes a lot of construction or dust, it is highly recommended that you
clean all of the screens after the wall installation and configuration are complete.
Please note:
Panel temperatures can increase 3-5°C with each vertically stacked unit. Accommodate
cooling as necessary to meet panel ambient specifications.
It is recommended that for inset walls 3 tall or less, a minimum of 13mm (0.5") gap be
left at the sides and a minimum of 25mm (1.0") gap be left at the bottom.
Ensure the LCD mounts are mounted flat, level, and plumb.
8.5

Cable Length Recommendations

Cable length performance may vary between different cables and sources. The recommended
maximum cable lengths are as follows:
HDMI
4K @ 50/60Hz: 8m (25 ft) maximum
4K @ 24/25/30Hz: 15m (50 ft) maximum
1080p @ 60Hz and lower resolutions: 20m (65 ft) maximum
DisplayPort
8m (25 ft) maximum
Planar VM Series User Manual