Number of cells
WARNING! Improperly adjusting the number of
a
cells selected can result in fire, property damage or
injury!
Batteries are usually composed of two or more cells, adjust
this setting to the number of cells contained inside the
battery (LiFe = 3.3V/cell, LiPo=3.7V/cell, NiMH-NiCd=1.2V
cell). The charger can charge LiPo/LiFe batteries with 2
to 4 cells (6.6-14.8V) and NiMH/NiCd batteries with 1 to
10 cells (1.2-12V).
Battery capacity
WARNING! Improperly adjusting the battery
a
capacity setting can overload the battery and result
in fire, property damage or injury!
Adjust this setting to the battery capacity value in mAh (mil-
liamp hour). The charger uses this setting to automatically
adjust the charge current to an optimal value of 1C, equal
to the battery capacity (ex. 4000mAh = 4A charge current).
NOTE: as an extra safety measure, when charging NiMH/
NiCd batteries, the charge will stop when the charged mAh
counter reaches the preset value (whether the battery is
actually full or not).
16 - English
Charge current
WARNING! Using a too high charge current can
a
overload the battery and result in fire, property
damage or injury! Always follow the battery manu-
facturer recommendations.
The charger automatically adjusts the charge current in
relation to the battery capacity setting (see above), but you
can adjust the charge current manually. The charge current
is adjustable in 0.1A steps up to 6A. The standard charge
current is 1C, which means one time the battery capacity,
ex. 4000mAh battery = 4A charge current. A higher charge
current charges the battery faster.
NOTE: depending on the battery type, the actual charge
current may be lower than the charge current setting.