5-2. Outdoor unit

¢ Discharge temperature thermistor
Temperature °F (°C)
-22.0 (-30.0)
-12.0 (-25.0)
-4.0 (-20.0)
5.0 (-15.0)
14.0 (-10.0)
23.0 (-5.0)
32.0 (0.0)
41.0 (5.0)
50.0 (10.0)
59.0 (15.0)
68.0 (20.0)
77.0 (25.0)
86.0 (30.0)
95.0 (35.0)
104.0 (40.0)
113.0 (45.0)
122.0 (50.0)
131.0 (55.0)
140.0 (60.0)
149.0 (65.0)
158.0 (70.0)
167.0 (75.0)
176.0 (80.0)
185.0 (85.0)
194.0 (90.0)
203.0 (95.0)
212.0 (100.0)
221.0 (105.0)
230.0 (110.0)
239.0 (115.0)
248.0 (120.0)
5-2. Outdoor unit
Resistance (kΩ)
1,013.11
729.09
531.56
392.31
292.91
221.09
168.60
129.84
100.91
79.12
62.55
49.84
40.01
32.35
26.34
21.58
17.79
14.75
12.30
10.32
8.70
7.36
6.27
5.36
4.60
3.96
3.43
2.98
2.60
2.27
2.00
- (03-41) -
Voltage (V)
0.06
0.09
0.12
0.16
0.21
0.28
0.36
0.46
0.57
0.71
0.86
1.03
1.23
1.43
1.65
1.88
2.11
2.34
2.57
2.79
3.00
3.19
3.37
3.54
3.69
3.83
3.96
4.07
4.17
4.26
4.33