2-4. E: 18. External communication error (Indoor unit)
Indicator
Indoor unit
Detective actuator
Indoor unit
Forecast of cause
Check point 1. Check the connection
•
Check any loose or removed connection betw een the main PCB to the external input and out-
put PCB.
-> If there is an abnormal condition, correct it by refer to the installation manual or the "DESIGN
& TECHNICAL MANUAL".
•
Check the connection condition on the external input and output PCB and the main PCB (If
there is loose connector, open cable or mis-wiring.)
Check point 2. Replace the external input and output PCB
If check point 1 do not improve the symptom, change external input and output PCB
Check point 3. Replace main PCB
If check point 2 do not improve the symptom, change main PCB
2-4. E: 18. External communication error (Indoor unit)
Operation indicator
Timer indicator
Economy indicator
Error code
External
communication
error
↓
↓
↓
End
Continuous flash
After receiving a signal from the external input and
output PCB, the same signal has not been received for
15 seconds.
Connection failure
External input and output PCB failure
- (03-7) -
1 time flash
8 time flash
E: 18
Main PCB
2. Troubleshooting with error code