E: 18. External Communication Error (Indoor Unit) - Fujitsu ASUG09LMAS Service Manual

Table of Contents

Advertisement

2-4. E: 18. External communication error (Indoor unit)

Indicator
Indoor unit
Detective actuator
Indoor unit
Forecast of cause
Check point 1. Check the connection
Check any loose or removed connection betw een the main PCB to the external input and out-
put PCB.
-> If there is an abnormal condition, correct it by refer to the installation manual or the "DESIGN
& TECHNICAL MANUAL".
Check the connection condition on the external input and output PCB and the main PCB (If
there is loose connector, open cable or mis-wiring.)
Check point 2. Replace the external input and output PCB
If check point 1 do not improve the symptom, change external input and output PCB
Check point 3. Replace main PCB
If check point 2 do not improve the symptom, change main PCB
2-4. E: 18. External communication error (Indoor unit)
Operation indicator
Timer indicator
Economy indicator
Error code
External
communication
error
End
Continuous flash
After receiving a signal from the external input and
output PCB, the same signal has not been received for
15 seconds.
Connection failure
External input and output PCB failure
- (03-7) -
1 time flash
8 time flash
E: 18
Main PCB
2. Troubleshooting with error code